An in vitro system was used to study the effect of tapping a jet nebuliser on the dose delivered to patients. Using a 2 ml fill, effective drug delivery had ceased by 3 minutes but a further 38% was delivered to the filter by 5 minutes if the chamber was tapped.
منابع مشابه
Jet and ultrasonic nebuliser output: use of a new method for direct measurement of aerosol output.
Output from jet nebulisers is calibrated traditionally by weighing them before and after nebulisation, but the assumption that the weight difference is a close measure of aerosol generation could be invalidated by the concomitant process of evaporation. A method has been developed for measuring aerosol output directly by using a solute (fluoride) tracer and aerosol impaction, and this has been ...
متن کاملNebulisers for patients with HIV infection and AIDS.
bacterium tuberculosis and other opportunistic infections. The choice of nebuliser and delivery system is If nebulisers are to be used within the hospital dictated by the need to deposit pentamidine then nebulisation should be carried out in a in the alveoli and to avoid deposition in the room separate from the main ward area, ideally oropharynx, trachea, and major bronchi. ...
متن کاملNebulisers: uses and abuses.
Jet nebulisers are used to deliver a wide range of drugs as aerosols. The British National Formullarv lists not only six bronchodilator solutions in doses up to 10 mg (available in single dose ampoules, multidose vials, or both), but also one corticosteroid, one prophylactic agent (sodium cromoglycate), and two mucolytics as being suitable for nebulisation.' In addition, nebulisers have been us...
متن کاملFactors influencing the size distribution of aerosols from jet nebulisers.
The size distribution of saline and bronchodilator (terbutaline) aerosol droplets generated from four widely used jet nebulisers (Acorn, Upmist, Turret, and Inspiron Mini-neb) has been measured with a Malvern 2200 Laser Particle Sizer. The mass median diameter of aerosol droplets generated by each nebuliser was strongly influenced by the driving flow rate of compressed air. By increasing the fl...
متن کاملWhich apparatus for inhaled pentamidine? A comparison of pulmonary deposition via eight nebulisers.
Aerosolised pentamidine 300 mg in 5 or 6 ml solution was administered via 8 different nebuliser systems to 12 patients with acquired immunodeficiency syndrome. Using 99mTc human serum albumin as an indirect marker for pentamidine, pulmonary, extrapulmonary (gastric and oropharyngeal) and alveolar deposition of pentamidine were measured using a gamma camera. Side effects (visual analogue scales)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood
دوره 70 6 شماره
صفحات -
تاریخ انتشار 1994