A simple device for washing out radioimmunoassay tubes.

نویسنده

  • K N Frayn
چکیده

The use of disposable polystyrene tubes for radioimmunoassay is now widespread. Washing out such tubes before disposal is tedious and time-consuming, especially if they contain dense charcoal or doubleantibody pellets. In this laboratory the simple device described below has much reduced the time and tedium involved in this task. It was constructed in a frew minutes for a cost of a few pence. *A hypodermic needle (19 g x 2 inches) is fixed to a length of plastic or rubber tubing (about 5 mm outside diameter, 4 mm bore) either by tying or simply by threading as shown in the figure. The plastic tube is connected to a pump which preferably discharges directly into a sink outlet or overflow. The needle is connected to a tap. Part of a disposable 1 ml-syringe makes a convenient adaptor. The apparatus is fixed in a clamp at a comfortable working height above a sink. For use water is passed through the needle (about 100-120 ml/min) and the pump turned on. Tubes to be washed are uncapped, held as shown over the apparatus for a few seconds, and discarded, conveniently into a plastic disposal bag fixed to the edge of the sink or bench. Obstinate

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple modification of a liquid scintillation counter to decrease cost of and time for radioimmunoassay.

A simple, inexpensive modification in the elevator mechanism of a liquid scintillation counter allows for radioimmunoassay tubes (12 X 75 mm) containing the antibody-bound radioligand to be counted directly, thereby obviating the need for counting vials and considerably decreasing the amount of fluor used. Furthermore, because assay and counting are all done in the same tube, the modification s...

متن کامل

Studies on Purification and Coatation of Polyclonal Antibody for Prolactin Solid Phase Radioimmunoassay in Human Serum

The objective of the present study was oriented to produce purified polyclonal antibody to prepare a prolactin solid phase coated tubes radioimmunoassay system. In the present study, production of polyclonal antibodies was carried out through immunization of three healthy white male mature New Zealand rabbits with a highly purified sheep prolactin antigen. The obtained anti-sera was purified us...

متن کامل

Mini-RIA: adaptation of conventional 125I-labeled radioimmunoassay to a 96-tube format.

Radioimmunoassay (RIA) employing iodinated ligands represents a popular measurement method for small molecules due to its excellent sensitivity and specificity. Yet performing RIAs of large numbers of tubes remains a tedious laboratory chore due to the need to individually handle tubes multiple times. We here present a method in which conventional 125I-labeled RIA ([125I] RIA) is adapted to a m...

متن کامل

Microbial contamination of suction tubes attached to suction instruments and preventive methods.

We investigated the microbial contamination of suction tubes attached to wall-type suction instruments. Microbial contamination of suction tubes used for endoscopy or sputum suction in hospital wards was examined before and after their disinfection. In addition, disinfection and washing methods for suction tubes were evaluated. Suction tubes (n=33) before disinfection were contaminated with 10(...

متن کامل

Microbial Contamination of Suction Tubes Attached to Suction Instrument and Its Preventive Methods

We investigated the microbial contamination of suction tubes attached to wall-type suction instrument. Microbial contamination of suction tubes used for endoscopy or sputum suction in wards was examined before and after their disinfection. In addition, disinfection and washing methods for suction tubes were evaluated. Suction tubes (N=33) before disinfection were contaminated with 102-108 colon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 1975