How cross screw length influences the stiffness of intrame-dullary nail systems
نویسندگان
چکیده
Fractures of long bones are commonly treated with intramedullary (IM) nails and they have been shown to have a very high success rate. Recently we have concerns with the use of the newer IM nailing systems, that uses longer cross screws, which have been developed with variation in implant designs. We believe that the newer implants provide less fracture stability, due to decreased stiffness of the IM nailing system. The aim of this study was to biomechanically determine the influence of the length of cross screw on the stiffness of the IM nailing system, using a composite model. Our test results confirmed our suspicion that the newer IM nailing system using longer cross screw-length is less stiff than traditional nailing systems using shorter cross screw length, during axial loading.
منابع مشابه
Distal locking in femoral intramedullary nailing system: Is one cross screw sufficient?
Introduction: The indications for intramedullary nail fixation of fractures of the femoral shaft have been greatly expanded by techniques of interlocking nailing. However, distal locking screw fixation remains the most technically demanding and problematic portion of the procedure and maybe responsible for as much as one-half of the exposure of the surgeon’s hands to radiation during the proced...
متن کاملThe biomechanics of varied proximal locking screw configurations in a synthetic model of proximal third tibial fracture fixation.
OBJECTIVE To determine if 1) angularly stable devices created by compressing ("locking") proximal locking screws to intramedullary nails using end caps or compression screws or 2) increasing the number of proximal screws from two to three increases the stiffness of intramedullary constructs that stabilize proximal third tibia fractures in a nonosteopenic bone model. METHODS Four proximal lock...
متن کاملThe Variable Angle Hip Fracture Nail Relative to the Gamma 3: A Finite Element Analysis Illustrating the Same Stiffness and Fatigue Characteristics
Ten percent of the 250,000 proximal femur fractures that occur in the United States each year are malreduced into a varus position after treatment. Currently, there is no cephalomedullary nail available that allows the physician to dynamically change the lag-screw-to-nail angle. The Variable Angle Nail (VAN) was designed to allow movement of the lag screw relative to the shaft of the nail. This...
متن کاملThe effects of distal interlocking screws on torsional stability in three-part intertrochanteric hip fractures
OBJECTIVE Many surgeons currently use long cephomedullary nails for the treatment of intertrochanteric fractures. The optimal indications for deploying distal interlocks are still debatable. This study examined the torsional biomechanical properties of 3-part intertrochanteric femur fractures in a cadaveric bone model using two different distal fixation strategies, an unlocked long cephalomedul...
متن کاملDetermination of the Best Method of Tibial Nail Length Estimation in Patients with Tibia Fracture
Background & Aims: Tibia fractures are the most common long bone fracture. Due to minimal soft tissue and its blood supply, inadequate treatment of injuries could be a major cause of morbidity and disability. The intramedullary nail is the preferred method of treatment; however, despite all previous studies, no accurate method to measure nail length prior to surgery exists as yet. Due to the im...
متن کامل