Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT) Based on Time-Resolved Immunochromatography

نویسندگان

  • Xiang-Yang Shao
  • Cong-Rong Wang
  • Chunmei Xie
  • Xian-Guo Wang
  • Rong-Liang Liang
  • Wei-Wen Xu
چکیده

Procalcitonin (PCT) is a current, frequently-used marker for severe bacterial infection. The aim of this study was to develop a cost-effective detection kit for rapid quantitative and on-site detection of PCT. To develop the new PCT quantitative detecting kit, a double-antibody sandwich immunofluorescent assay was employed based on time-resolved immunofluorescent assay (TRFIA) combined with lateral flow immunoassay (LFIA). The performance of the new developed kit was evaluated in the aspects of linearity, precision, accuracy, and specificity. Two-hundred thirty-four serum samples were enrolled to carry out the comparison test. The new PCT quantitative detecting kit exhibited a higher sensitivity (0.08 ng/mL). The inter-assay coefficient of variation (CV) and the intra-assay CV were 5.4%-7.7% and 5.7%-13.4%, respectively. The recovery rates ranged from 93% to 105%. Furthermore, a high correlation (n = 234, r = 0.977, p < 0.0001) and consistency (Kappa = 0.875) were obtained when compared with the PCT kit from Roche Elecsys BRAHMS. Thus, the new quantitative method for detecting PCT has been successfully established. The results indicated that the newly-developed system based on TRFIA combined with LFIA was suitable for rapid and on-site detection for PCT, which might be a useful platform for other biomarkers in point-of-care tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-Resolved Fluorescent Immunochromatography of Aflatoxin B1 in Soybean Sauce: A Rapid and Sensitive Quantitative Analysis

Rapid and quantitative sensing of aflatoxin B1 with high sensitivity and specificity has drawn increased attention of studies investigating soybean sauce. A sensitive and rapid quantitative immunochromatographic sensing method was developed for the detection of aflatoxin B1 based on time-resolved fluorescence. It combines the advantages of time-resolved fluorescent sensing and immunochromatogra...

متن کامل

Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies

Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...

متن کامل

Dual-Quantum-Dots-Labeled Lateral Flow Strip Rapidly Quantifies Procalcitonin and C-reactive Protein.

In the article, a dual-quantum-dots-labeled (dual-QDs-labeled) lateral flow strip (LFS) method was developed for the simultaneous and rapid quantitative detection of procalcitonin (PCT) and C-reactive protein (CRP) in the blood. Two QD-antibody conjugates with different fluorescence emission spectra were produced and sprayed on the LFS to capture PCT and CRP in the blood. Furthermore, a double ...

متن کامل

Significance of Serum Procalcitonin Level in the Early Diagnosis of Neonatal Sepsis

Background: Sepsis in neonates presents itself with non-specific clinical features which makes early diagnosis difficult. However, procalcitonin (PCT) and other inflammatory markers have recently been considered as sensitive markers for the early detection of neonatal sepsis. Therefore, the present study aimed to determine the diagnostic value of PCT in the early detection of neonatal sepsis an...

متن کامل

Development, evaluation, and application of lateral-flow immunoassay (immunochromatography) for detection of rotavirus in bovine fecal samples.

A lateral-flow immunoassay (LFT) was developed to detect bovine rotavirus in fecal samples. Using samples (n = 74) from diarrheic calves, a comparison of the LFT with a commercial latex agglutination test (LAT) and transmission electron microscopy (EM) was conducted. When EM was used as the reference method, initial studies of 29 samples indicated 70 and 80% sensitivities of the LFT and LAT, re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017