Challenges of maintaining breath-hold conformity for breast patients while using the deep inspiration breath-hold technique

نویسندگان

  • Marianne Dabbs
  • Matt Bolt
  • Sandra Dymond
چکیده

Deep inspiration breath-hold (DIBH) is used for whole breast radiotherapy, as a means of providing better dose homogeneity. This can be achieved by lower doses to the organs at risk, less patient movement and better set up. Most patients offered DIBH treatment are left-sided breast cancer, or ductal carcinoma in situ (DCIS) patients, due to the proximity of the heart to the chest wall so it is nearer the radiation field. However, if lung sparing is essential for the patient, DIBH offers a solution for right-sided breast cancer patients also. St Luke’s Cancer Centre at Royal Surrey County Hospital introduced a DIBH service in June 2012 for left-sided breast cancer patients. This service was initially introduced at a low level, with the increase in capacity over the course of 18 months achieving a service roll out to all left-sided breast patients, and selected right-sided breast patients. The Varian Real-time Position Management (RPM) system is used in the GE computed tomography (CT) scanner, and on the Varian Linacs. The marker box is placed horizontally onto the patient’s chest. This permits the in-room camera to detect the reflective markers. An assessment of the patient’s ability to hold their breath must be taken at the CT scanning appointment. Several practice sessions are performed before the DIBH CT scan is acquired to ensure that the patient can maintain a reproducible and constant deep inspiration breath-hold for the duration of the scan and for treatment, and is comfortable with the requirements. The patient must be able to take regular breath-holds, each being for a minimum of 15 seconds. It is also worth noting that the threshold (amplitude of the breathing trace) of the breath-hold should be assessed at this point to ensure the breath is deep enough to ensure reproducibility at treatment. Once the patient is comfortable with this procedure the DIBH scan is performed during a single breath-hold. To align the patient for treatment they are required to be in breath-hold. Once treatment commences, the linac will only deliver radiation when the marker box is detected in the breath threshold window as defined during the CT appointment using the RPM system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer

Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...

متن کامل

A gated deep inspiration breath‐hold radiation therapy technique using a linear position transducer

For patients with thoracic and abdominal lesions, respiration-induced internal organ motion and deformations during radiation therapy are limiting factors for the administration of high radiation dose. To increase the dose to the tumor and to reduce margins, tumor movement during treatment must be minimized. Currently, several types of breath-synchronized systems are in use. These systems inclu...

متن کامل

Feasibility study of deep inspiration breath-hold based volumetric modulated arc therapy for locally advanced left sided breast cancer patients.

BACKGROUND The purpose of this study was to assess the feasibility of deep inspiration breath-hold (DIBH) based volumetric modulated arc therapy (VMAT) for locally advanced left sided breast cancer patients undergoing radical mastectomy. DIBH immobilizes the tumor bed providing dosimetric benefits over free breathing (FB). MATERIALS AND METHODS Ten left sided post mastectomy patients were imm...

متن کامل

Evaluation of target and cardiac position during visually monitored deep inspiration breath‐hold for breast radiotherapy

A low-resource visually monitored deep inspiration breath-hold (VM-DIBH) technique was successfully implemented in our clinic to reduce cardiac dose in left-sided breast radiotherapy. In this study, we retrospectively characterized the chest wall and heart positioning accuracy of VM-DIBH using cine portal images from 42 patients. Central chest wall position from field edge and in-field maximum ...

متن کامل

Volumetric Modulated Arc Therapy (VMAT) combined with deep inspiration breath hold (DIBH) technique for adjuvant irradiation for cancer of the left breast

Purpose: We describe here the implementation of a very simple approach of combining Volumetric Arc Therapy (VMAT) and the deep inspiration breath hold technique (DIBH) without any costly equipment, in order to reduce the dose at the heart and decrease the cardiotoxicity risk for left sided breast radiotherapy (RT). Methods and Materials: Forty nine patients were treated with the DIBH-VMAT techn...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014