Genesis of Still's murmurs: a controlled Doppler echocardiographic study.
نویسندگان
چکیده
OBJECTIVE The origin of innocent systolic murmurs is uncertain. This study was designed to evaluate the relative contribution in the same subjects of the main factors implicated in the genesis of vibratory innocent systolic murmurs--that is, the presence of left ventricular bands and increased left ventricular flow indices--and to examine evidence for turbulence in relation to these findings. PATIENTS 40 children with innocent systolic murmurs and 40 paired controls without murmurs were matched for age and body surface area. DESIGN These subjects were examined prospectively by cross sectional echocardiography with pulsed and continuous wave Doppler and colour flow mapping. SETTING A tertiary referral centre for paediatric cardiology. RESULTS Left ventricular bands were significantly more prevalent in patients with innocent murmurs (70%) than in controls (48%) but only if apical bands were included (p = 0.039). Cases had significantly higher aortic peak flow velocities (p less than 0.001), flow integrals (p = 0.001), and stroke volumes (p = 0.014), and significantly lower heart rates (p = 0.033) than controls. There were no significant differences between cases and controls in mean aortic diameter, cardiac output, or ejection fraction. There was no evidence of turbulence in the left ventricle or outflow tract in any individual but curvilinear periodic vibrations and audible "whoops" were detected in the left ventricle by pulsed wave Doppler echocardiography. These were significantly more common in cases than controls (p less than 0.01) but were not related to the presence of bands. CONCLUSIONS Innocent systolic murmurs were unrelated to aortic size but they were strongly associated with higher aortic flow volume and velocity, with relative bradycardia, and with evidence of vibratory phenomena in the left ventricle. The role of left ventricular bands remains uncertain.
منابع مشابه
Echocardiographic findings in athletic horses with pulmonary regurgitation
BACKGROUND: Determining the clinical significance of cardiac murmurs is widely considered in equine practice. Pulmonary murmurs are commonly detected in athletic horses. Echocardiography plays a leading role in assessment of these murmurs. OBJECTIVES: Echocardiographic evaluation of horses with pulmonary regurgitation and determining the importance of pulmonary valve murmurs. METHODS: A total n...
متن کاملNormal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran
Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...
متن کاملEchocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs
Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the twodimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. ...
متن کاملLeft basilar systolic murmur in retired racing greyhounds.
Nineteen of 28 (67%) Greyhounds enrolled in the Blood Donor Program at The Veterinary Teaching Hospital, The Ohio State University (Columbus, OH), had a left basilar systolic murmur. Ten Greyhounds with murmurs and 9 without murmurs were evaluated to gain knowledge about the pathogenesis of this murmur. Echocardiograms were performed without sedation by means of a GE Vivid 7 Echocardiographic S...
متن کاملDoppler echocardiography. The localization of cardiac murmurs.
SUMMARY A range-gated pulsed Doppler flowmeter has recently been developed that measures the average velocity of blood flow within a small tear-drop shaped (4 mm by 2 mm) sample volume. Unlike the continuous wave Doppler, the distance from the transducer face to the sampling site can be continuously varied by a range adjustment knob. Twenty patients with cardiac murmurs were evaluated in a noni...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 66 3 شماره
صفحات -
تاریخ انتشار 1991