Spectral Entropy Parameters during Rapid Ventricular Pacing for Transcatheter Aortic Valve Implantation

نویسندگان

  • Tadeusz Musialowicz
  • Antti Valtola
  • Mikko Hippeläinen
  • Jari Halonen
  • Pasi Lahtinen
چکیده

The time-frequency balanced spectral entropy of the EEG is a monitoring technique measuring the level of hypnosis during general anesthesia. Two components of spectral entropy are calculated: state entropy (SE) and response entropy (RE). Transcatheter aortic valve implantation (TAVI) is a less invasive treatment for patients suffering from symptomatic aortic stenosis with contraindications for open heart surgery. The goal of hemodynamic management during the procedure is to achieve hemodynamic stability with exact blood pressure control and use of rapid ventricular pacing (RVP) that result in severe hypotension. The objective of this study was to examine how the spectral entropy values respond to RVP and other critical events during the TAVI procedure. Twenty one patients undergoing general anesthesia for TAVI were evaluated. The RVP was used twice during the procedure at a rate of 185 ± 9/min with durations of 16 ± 4 s (range 8–22 s) and 24 ± 6 s (range 18–39 s). The systolic blood pressure during RVP was under 50 ± 5 mmHg. Spectral entropy values SE were significantly declined during the RVP procedure, from 28 ± 13 to 23 ± 13 (p < 0.003) and from 29 ± 12 to 24 ± 10 (p < 0.001). The corresponding values for RE were 29 ± 13 vs. 24 ± 13 (p < 0.006) and 30 ± 12 vs. 25 ± 10 (p < 0.001). Both SE and RE values returned to the pre-RVP values after 1 min. Ultra-short hypotension during RVP changed the spectral entropy parameters, however these indices reverted rapidly to the same value before application of RVP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unexpected and fatal hemodynamic collapse during transapical transcatheter aortic valve implantation -A case report-

Although transcatheter aortic valve implantation (TAVI) is generally accepted as an alternative or promising treatment option for patients with decompensated cardiovascular disease in an inoperable or high-risk condition, severe hypotension and/or arrhythmia associated with rapid ventricular pacing still poses a challenge to many clinicians. This report describes a 79-year-old patient who exper...

متن کامل

Peritoneal migration of an epicardial pacemaker.

therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association. Europace 2013;15:1070–118. 20. Urena M, Webb JG, Eltchaninoff H, Munoz-Garcia AJ, Bouleti C, Tamburino C et al. Late cardiac death in patients undergoing transcatheter aortic valve replacement: incidence and predictors of advanced heart failure and sudden cardiac death. J ...

متن کامل

Transcatheter aortic valve implantation: anesthetic considerations.

Aortic valvular stenosis remains the most common debilitating valvular heart lesion. Despite the benefit of aortic valve (AV) replacement, many high-risk patients cannot tolerate surgery. AV implantation treats aortic stenosis without subjecting patients to sternotomy, cardiopulmonary bypass (CPB), and aorta cross-clamping. This transcatheter procedure is performed via puncture of the left vent...

متن کامل

Noninvasive pacing during transfemoral implantation of the Edwards SAPIEN valve for tricuspid valve bioprosthesis stenosis

Introduction Transcatheter implantation of balloon expandable valves in high-risk patients with degenerated tricuspid bioprostheses has been reported since 2010 [1, 2]. Although there have been cases where the SAPIEN valve was implanted in the tricuspid position without rapid pacing [3, 4], invasive rapid ventricular pacing is usually applied during valve deployment. We present a case report do...

متن کامل

A Simplified Protocol for Transcatheter Aortic Valve Implantation that Reduces Procedure-related Risk

Objectives: Transcatheter Aortic Valve Implantation is now a well-established procedure and continuous development has improved the technique. The object of this paper is to describe the successive steps taken at our department to improve our protocol, resulting in a more effective and patient-safe procedure. Design: An echo-guided method for aortic cusp alignment was used in 229 patients. In 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Entropy

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2017