Physiologic anisocoria under various lighting conditions
نویسندگان
چکیده
Purpose To evaluate the measurement of anisocoria in a group of ocular healthy subjects using a standardized protocol in scotopic, mesopic, and photopic lighting conditions, and determine the optimal threshold of difference in pupil diameter in determining physiologic anisocoria. Methods Right and left pupil diameters of 126 ocular healthy subjects with a mean age 30.5±7.8 years (40 males and 86 females) were measured sequentially under photopic conditions using a monocular infrared pupillometer. A sub-group of 51 individuals had right and left pupil measurements performed under three additional lighting conditions, allowing for a 2-minute recovery between measurements. A white light emitting diode (LED) in the eyecup of the pupillometer produced three controlled light settings: scotopic (0 lux), low mesopic (0.3 lux), and high mesopic (3 lux). The criterion for anisocoria was defined as ≥0.4 mm difference in pupil diameter between the eyes. Results In the 126 subjects tested, 23.8% (n=30) exhibited anisocoria in photopic conditions. In the sub-group measured under three additional light settings, 43.1% (n=22) exhibited anisocoria in scotopic conditions, 43.1% (n=22) in low mesopic conditions, and 47.1% (n=24) in high mesopic conditions. Approximately 73% of subjects exhibited anisocoria in at least one light setting, while only approximately 8% had anisocoria in every light setting. When the criterion for anisocoria was shifted to ≥0.2 mm or ≥0.6 mm, the prevalence of anisocoria shifted significantly. Using a higher cutoff of ≥0.6 mm effectively reduced the number of healthy individuals who exhibit anisocoria in every light setting to almost zero. Conclusion Based on our data, anisocoria is more prevalent under varied lighting conditions. To ensure the anisocoria is due to physiologic reasons, one should ensure that it is present under all lighting conditions to avoid excessive false positives.
منابع مشابه
Anisocoria. Variation and clinical observation with different conditions of illumination and accommodation.
Variations in anisocoria in light and dark conditions are used to help diagnose normal and pathologic conditions; however, there have been few observations of anisocoria in different lighting and accommodative conditions. The authors measured pupil size photographically in a group of normal subjects examined in six conditions that were controlled for illumination and accommodation. Greater vari...
متن کاملAnisocoria under general anesthesia with Propofol
Anisocoria during anesthesia is very rare, but may indicate life-threatening neurologic injuries and create tremendous condition. A 23-year-old male patient was anesthetized with fentanyl and propofol. Thirty minutes after inducing anesthesia, unilateral mydriasis was detected. The duration of surgery was shortened for prompt evaluation of the pupils. At the end of the operation neither vision ...
متن کاملObject Recognition under Various Lighting Conditions
This paper describes object recognition under various lighting conditions for a robot which finds a user-specified object and brings it to the user. The system first constructs object models under a known lighting condition. Because the lighting condition in model construction is different from that in object recognition, the system needs to transform the model’s color for the current lighting ...
متن کاملsurvey effect of illuminance source on alertness in a laboratory design
Background and aims: Workplaces with poor lighting conditions often created occupational accidents or illness. This occurs because light cause visual and nonvisual effects on numerous physiological variables, such as the human sleep-wake cycle and cognitive performance. Indoor lighting conditions, as one aspect of the work environment, Influence on occupant’s mood, well-being, task performance ...
متن کاملModeling and Simulation of Traffic Lights on the High Contrast and Brightness Conditions and Structure Technology
Nowadays, the use of intelligent control systems to reduce human error is one of the most popularresearch fields. Design and implementation of such controllers requires to actual knowledge of theenvironment conditions. Traffic lights as one of the inputs of intelligent control systems are significant.usually the traffic lights have the various physical structure. also, generally in image proces...
متن کامل