A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer body fluids module and comparison with hemacytometer cell counts.
نویسندگان
چکیده
Manual hemacytometer cell counting of body fluids is labor-intensive and requires skilled testing personnel. We performed a multicenter evaluation of the Iris iQ200 automated microscopy analyzer Body Fluids Module (Iris Diagnostics, Chatsworth, CA) and compared 350 iQ200 body fluid cell counts with manual hemacytometer cell counts. Within-run imprecision, expressed as coefficient of variation (CV), ranged from 2.6% to 5.9% for RBC counts between 875 and 475 x 10(6)/L and from 4.2% to 6.5% for nucleated cell counts between 820 and 590 x 10(6)/L. The lower limits of detection, based on a CV of 20% or less, were 30 and 35 x 10(6)/L for RBCs and nucleated cells, respectively. There was very good agreement between automated iQ200 and manual body fluid cell counts based on slopes and r2 values. The iQ200 has satisfactory performance for enumerating RBCs and nucleated cells in most body fluids, with the exception of cerebrospinal fluid specimens that contain low cell numbers.
منابع مشابه
Analytic performance of the iQ200 automated urine microscopy analyzer and comparison with manual counts using Fuchs-Rosenthal cell chambers.
Automated instruments that can examine urine for cells and particles have reduced the need for labor-intensive manual microscopy. We evaluated the performance of the Iris iQ200 Automated Urine Microscopy Analyzer (Iris Diagnostics, Chatsworth, CA) and compared results with manual cell and particle counts using Fuchs-Rosenthal counting chambers. Within-run imprecision (coefficient of variation) ...
متن کاملThe clinical reliability of automated cerebrospinal fluid cell counts on the Beckman-Coulter LH750 and Iris iQ200.
Although automation has improved the accuracy and precision of blood cell counts and is more rapid and less labor-intensive, cerebrospinal fluid (CSF) samples are still counted manually. We compared the IRIS iQ200 Body Fluids Module (Iris Diagnostics, Chatsworth, CA) and the Beckman-Coulter LH750 (Beckman-Coulter, Brea, CA) with manual counts and evaluated the impact of automation on the labora...
متن کاملAutomated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.
BACKGROUND Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. METHODS A total of 3...
متن کاملComparison of Cobas 6500 and Iris IQ200 fully-automated urine analyzers to manual urine microscopy
INTRODUCTION Urine screening is achieved by either automated or manual microscopic analysis. The aim of the study was to compare Cobas 6500 and Iris IQ200 urine analyzers, and manual urine microscopic analysis. MATERIALS AND METHODS A total of 540 urine samples sent to the laboratory for chemical and sediment analysis were analyzed on Cobas 6500 and Iris IQ200 within 1 hour from sampling. One...
متن کاملEvaluation of pleural and ascitic fluid analysis on the Sysmex XE-5000 hematology analyzer
Introduction: Body fluid (BF) analysis is critical to the diagnosis and monitoring of several pathological conditions. The limitations of manual cell counts have led to greater interest in the development of automated BF analysis. Objective: To evaluate the analytical performance of the Sysmex XE-5000 hematology analyzer in the analysis of pleural and ascitic fluids in the laboratory routine of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of clinical pathology
دوره 129 3 شماره
صفحات -
تاریخ انتشار 2008