MRI-determined left ventricular "crescent effect": a consequence of the slight deviation of contents of the pericardial sack from the constant-volume state.

نویسندگان

  • Emily A Waters
  • Andrew W Bowman
  • Sándor J Kovács
چکیده

During one cardiac cycle, the volume encompassed by the pericardial sack in healthy subjects remains nearly constant, with a transient +/-5% decrease in volume at end systole. This "constant-volume" attribute defines a constraint that the longitudinal versus radial pericardial contour dimension relationship must obey. Using cardiac MRI, we determined the extent to which the constant-volume attribute is valid from four-chamber slices (two-dimensional) compared with three-dimensional volumetric data. We also compared the relative percentage of longitudinal versus radial (short-axis) change in cross-sectional area (dimension) of the pericardial contour, thereby assessing the fate of the +/-5% end-systolic volume decrease. We analyzed images from 10 normal volunteers and 1 subject with congenital absence of the pericardium, obtained using a 1.5-T MR scanner. Short-axis cine loop stacks covering the entire heart were acquired, as were single four-chamber cine loops. In the short-axis and four-chamber slices, relative to midventricular end-diastolic location, end-systolic pericardial (left ventricular epicardial) displacement was observed to be radial and maximized at end systole. Longitudinal (apex to mediastinum) pericardial contour dimension change and pericardial area change on the four-chamber slice were negligible throughout the cardiac cycle. We conclude that the +/-5% end-systolic decrease in the volume encompassed by the pericardial sack is primarily accounted for by a "crescent effect" on short-axis views, manifesting as a nonisotropic radial diminution of the pericardial/epicardial contour of the left ventricle. This systolic drop in cardiac volume occurs primarily at the ventricular level and is made up during the subsequent diastole when blood crosses the pericardium in the pulmonary venous Doppler D wave during early rapid left ventricular filling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship of pulmonary vein flow to left ventricular short-axis epicardial displacement in diastole: model-based prediction with in vivo validation.

Previous studies in healthy humans have established that the (approximately 850 ml) volume enclosed by the pericardial sac is nearly constant over the cardiac cycle, exhibiting a transient approximately 5% decrease (approximately 40 ml) from end diastole to end systole. This volume decrease manifests as a "crescent" at the ventricular free wall level when short-axis MRI images of the epicardial...

متن کامل

Left atrial conduit volume is generated by deviation from the constant-volume state of the left heart: a combined MRI-echocardiographic study.

Although modeling the four-chambered heart as a constant-volume pump successfully predicts causal physiological relationships between cardiac indexes previously deemed unrelated, the real four-chambered heart slightly deviates from the constant-volume state by ventricular end systole. This deviation has consequences that affect chamber function, specifically, left atrial (LA) function. LA attri...

متن کامل

Sexual Dimorphism in Volume of the Cerebral Hemispheres and Lateral Ventricles in Schizophrenia Using Magnetic Resonance Imaging

Purpose: This study is designed to determine the sexual dimorphism pattern in volume of the cerebral hemispheres and lateral ventricles in schizophrenia using magnetic resonance imaging (MRI) and to compare it with normal sexual dimorphism pattern in healthy brains. Materials and Methods: This study is performed on 29 healthy volunteers (21 males, 8 females) and 29 patients suffered from schiz...

متن کامل

تعیین و مقایسه یافتههای اکوکاردیوگرافی بر اساس وضعیت Cardio Thoracic Ratio در گرافی قفسه سینه

Introduction: Chest X–Ray is one of the most common method of imaging. Cardio Thoracic Ratio ( CTR ) is one of the parameters of Chest X–Ray that is used for determining cardiac enlargement. Echocardiography as compared to Chest X–Ray is expensive and all centers dont have it, but it can determine heart size, valvular diseases, Ejection Fraction, Left Ventricular Hypertrophy (LVH), Pericardial...

متن کامل

Assessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques

The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 288 2  شماره 

صفحات  -

تاریخ انتشار 2005