[The modular MML revision system in knee revision and tumor arthroplasty].

نویسندگان

  • L Gerdesmeyer
  • A Töpfer
  • J Kircher
  • H Grundei
  • P Diehl
چکیده

Increasing age and a higher level of mobility lead to an increasing incidence in revision arthroplasty after total knee replacement and tumor surgery. So far, the reconstruction of large defects in bony and soft tissue environments can be accomplished by the modern modular components of revision implants. The consecutive reconstruction of the extensor mechanism in extended revision has its own drawbacks and is often associated with significant functional limitations for the patient. Specially designed implants and methods are required to generate good functional results. The modular knee revision system MML provides specific modifications of the tibial component for reconstruction of the extensor mechanism. Combined with artificial strips, an excellent functional outcome could be achieved. In this study, 70 patients were operated with the MML endoprosthesis in knee revision or tumor surgery. An excellent functional outcome could be determined. At 7 years after surgery, an average of 32+/-13 points was achieved on the Oxford Knee Score. The outcome measurement using the functional scoring system of the American Knee Society (AKS score) showed similarly good results with 71+/-25 points out of 100. A minor deficit of only 2 degrees in active extension could be observed after reconstruction of the extensor mechanism. In conclusion, we have demonstrated that the MML modular revision system is appropriate for reconstruction of segmental bone defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outcome of revision in comparison with primary total knee arthroplasty in Iran

 Abstract  Background: In the recent decade, many primary total knee arthroplasties have  been carried out in Iran and the number of revision cases is expected to rise with the  aging population. The aim of this study was to report the outcome of revision surgery  in the country and make a comparison between the outcome of revision and that of  the primary arthroplasty.  Methods: Retrospectivel...

متن کامل

Short-Term Results of the DePuy Global Unite Platform Shoulder System: A Two-Year Outcome Study

Background: The Global Unite Shoulder System is the next generation of implant from the Depuy Global Shoulderline. The primary feature of the Global Unite is adaptability through the interchangeable modular bodies, modular suturecollars, and stems. Short-term functional and radiographic outcomes of the Global Unite Platform Shoulder Systemwere assessed as well as complication and revision rates...

متن کامل

Distal femoral replacement with the MML system: a single center experience with an average follow-up of 86 months

BACKGROUND The aim of this study was to compare the functional outcomes and complication rates after distal femoral replacement (DFR) performed with the modular Munich-Luebeck (MML) modular prosthesis (ESKA/Orthodynamics, Luebeck, Germany) in patients being treated for malignant disease or failed total knee arthroplasty. METHODS A retrospective review of patient charts and a functional invest...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

Results of a Modular Revision System in Total Knee Arthroplasty.

BACKGROUND Revision total knee arthroplasty (TKA) poses unique challenges compared with primary TKA such as bone loss, deformity, and ligament instability. Modular component options allow flexibility to deal with these complexities. The purpose of this study was to evaluate midterm outcomes for revision TKA using a modular revision knee system with complete interchangeability and multiple optio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Der Orthopade

دوره 35 9  شماره 

صفحات  -

تاریخ انتشار 2006