Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers

نویسندگان

  • Junya Ako
  • Masao Yamasaki
  • Tomomi Koizumi
  • Ryota Sakurai
  • Yoichiro Hongo
  • Stephen G. Worthley
  • Darren L. Walters
  • Ian T. Meredith
چکیده

Background—Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Methods and Results—Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound–detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7 4.0, Endeavor: 17.5 10.1, ZoMaxx: 14.6 8.1, Driver: 29.4 17.2%; P 0.001). Greater maximum cross-sectional narrowing and higher neointima-free frame ratio, suggesting less neointimal coverage, were observed in Resolute compared with other stent groups. Multiple regression analysis confirmed that the biodurable polymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. Conclusions—The different polymer formulations significantly affect the relative amount of neointima for zotarolimuseluting stents. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079. (Circ Cardiovasc Interv. 2011;4:00-00.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

BACKGROUND Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS Data were obtained from...

متن کامل

Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.

OBJECTIVES We performed this study to investigate the vascular response in early period after zotarolimus-eluting stent (ZES) (Endeavor Sprint, Medtronic CardioVascular, Minneapolis, Minnesota) implantation. BACKGROUND The ZES has different characteristics, with biocompatible polymer and rapid drug-elution, compared with the first-generation drug-eluting stents (DES). METHODS The ENDEAVOR O...

متن کامل

Early neointimal coverage and vasodilator response following biodegradable polymer sirolimus-eluting vs. durable polymer zotarolimus-eluting stents in patients with acute coronary syndrome –HATTRICK-OCT trial.

BACKGROUND Patients at high bleeding risk would benefit from a shorter dual antiplatelet therapy after PCI. Compared to first-generation devices, the design of newer generation drug-eluting stents may facilitate more rapid anatomical and functional healing of stented vessel based on thinner stent platforms, biodegradable/biocompatible polymers and rapid drug elution. METHODS AND RESULTS Forty...

متن کامل

Polymer-free sirolimus- and probucol-eluting versus new generation zotarolimus-eluting stents in coronary artery disease: the Intracoronary Stenting and Angiographic Results: Test Efficacy of Sirolimus- and Probucol-Eluting versus Zotarolimus-eluting Stents (ISAR-TEST 5) trial.

BACKGROUND Durable polymer coatings have been implicated in mid- and long-term adverse events after drug-eluting stent implantation. A polymer-free dual-drug sirolimus- and probucol-eluting stent and a new generation permanent polymer zotarolimus-eluting stent are recently developed technologies demonstrating encouraging results. METHODS AND RESULTS In a clinical trial with minimal exclusion ...

متن کامل

Randomized Trial of Polymer-Free Sirolimus- and Probucol-Eluting Stents Versus Durable Polymer Zotarolimus-Eluting Stents: 5-Year Results of the ISAR-TEST-5 Trial.

OBJECTIVES The aim of this study was to evaluate the late clinical performance of a polymer-free sirolimus- and probucol-eluting stent compared with a new-generation durable polymer-based zotarolimus-eluting stent. BACKGROUND It was previously shown that polymer-free sirolimus- and probucol-eluting stents were noninferior to zotarolimus-eluting stents at 12 months. However, long-term follow-u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011