Studies on the mechanism of cell elongation in Blepharisma japonicum. II. Changes of the membrane potential measured by an electrode sensitive to tetraphenyl phosphonium.
نویسندگان
چکیده
An electrode sensitive to tetraphenyl phosphonium (TPP+) was applied to monitor the changes in the membrane potential of the ciliate Blepharisma japonicum during the process of cell elongation. Uptake of TPP+ by Blepharisma cells was observed when they were incubated in a medium containing 2 x 10(-6)M TPP+. Subsequent light stimulation (3,000 lux) led to an efflux of accumulated TPP+ from the cells, indicating that depolarization of the plasma membrane occurred with the concomitant cell elongation. TPP+ efflux was always observed whenever cell elongation was induced in response to various stimuli: valinomycin (10(-6)M), K+ (30 mM), Co2+ (5 mM), and Ca2+ (5 mM). Furthermore, elongation was also evoked by electrical stimulation. These observations indicate that membrane depolarization is involved in the process of cell elongation in Blepharisma.
منابع مشابه
Construction of an Ion-Selective Eelectrode for Determination of permanganate Ion
A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...
متن کاملCalcium movement and membrane potential changes in the early phase of neutrophil activation by phorbol myristate acetate: a study with ion- selective electrodes
To quantitate calcium movements and membrane potential changes in stimulated neutrophils, we have measured net fluxes of Ca2+ and of the lipophilic cation tetraphenyl phosphonium by a very sensitive ion-selective electrode system. Activation of neutrophils by 3 X 10(-8) M phorbol 12-myristate, 13-acetate induces a release of approximately 20% of total cell calcium, with an initial lag period of...
متن کاملCu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone
In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...
متن کاملDetermination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier
Cobalt has great biological effects on human beings and also other living organisms, hence its determination is very important. In this regard, a novel coated graphite electrode was designed for determination of Co2+ ions by exploiting 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier, for the first time. The foremost function was witnessed from the membrane composition of PVC...
متن کاملHigh-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium
N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cell structure and function
دوره 15 5 شماره
صفحات -
تاریخ انتشار 1990