An analysis of the best method for evaluating anteversion of the acetabular component after total hip replacement on plain radiographs.

نویسندگان

  • T Nomura
  • M Naito
  • Y Nakamura
  • T Ida
  • D Kuroda
  • T Kobayashi
  • T Sakamoto
  • H Seo
چکیده

Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°). Measurements using Widmer's method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001). This study has shown that Widmer's method is the best for evaluating the anteversion of the acetabular component on plain radiographs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs

BACKGROUND Several radiological methods for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) exist, and no single standardized method has been established. We evaluated the reliability and accuracy of six widely utilized methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., Ackland et al., and Woo and Morrey) for measuring anteversion on plain rad...

متن کامل

Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis

Background: Although abduction of the acetabular component is considered to predict factors for polyethylene wear attributable to osteolysis, other radiographic factors have yet to be elucidated. The purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiogr...

متن کامل

Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?

PURPOSE The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. MATERIALS AND METHODS We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and com...

متن کامل

Accuracy of Component Placement in Robotic-Assisted Total Hip Arthroplasty.

Robotic-assisted total hip arthroplasty (THA) is a recent platform introduced to decrease the risk of malpositioned components. The goals of this study were to determine whether intraoperative data on robotic-assisted THA acetabular component position accurately predict postoperative radiographic acetabular component position and to determine whether intraoperative data on robotic-assisted THA ...

متن کامل

A simple mathematical standardized measurement of acetabulum anteversion after total hip arthroplasty

We invented a standardization method to measure the cup’s anteversion after total hip arthroplasty without the influence of patient’s position. We measured 68 radiographs of 10 patients after total hip replacement (THR) and calculated the error of each measurement, defined as the difference with the average of the same measuring method on the same patient. We also calculated the repeatability s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The bone & joint journal

دوره 96-B 5  شماره 

صفحات  -

تاریخ انتشار 2014