Feasibility, complications, morbidity, and mortality results at 6 months for aneurysm treatment with the Flow Re-Direction Endoluminal Device: report of SAFE study.

نویسندگان

  • Laurent Pierot
  • Laurent Spelle
  • Jérôme Berge
  • Anne-Christine Januel
  • Denis Herbreteau
  • Mohamed Aggour
  • Michel Piotin
  • Alessandra Biondi
  • Xavier Barreau
  • Charbel Mounayer
  • Chrisanthi Papagiannaki
  • Jean-Paul Lejeune
  • Jean-Yves Gauvrit
  • Vincent Costalat
چکیده

BACKGROUND AND PURPOSE Flow diverters are increasingly used for the treatment of intracranial aneurysms. Evaluation of the first devices available for clinical use showed high efficacy of this treatment although safety results were worse compared with coiling or balloon-assisted coiling. The Safety and Efficacy Analysis of FRED Embolic Device in Aneurysm Treatment (SAFE) trial is a single-arm, multicenter, prospective study conducted to precisely analyze the safety and efficacy of the FRED and FRED Jr devices. METHODS Unruptured and recanalized aneurysms located in the anterior circulation treated with FRED and FRED Jr were prospectively included. Adverse events were independently evaluated by a Clinical Event Committee with a vascular neurosurgeon and an interventional neuroradiologist. Primary safety outcome measures were morbidity and mortality rates at 6 months after treatment. RESULTS A total of 103 patients/aneurysms were included in 13 interventional neuroradiology (INR) centers. Aneurysm locations were supraclinoid internal carotid artery (ICA) in 71 (68.9%), cavernous ICA in 15 (14.6%), anterior cerebral artery or anterior communicating artery in nine (8.7%), and middle cerebral artery in eight (7.8%). Aneurysms were small (<10 mm) in 71 patients (68.9%). Treatment was successfully performed in 98/103 patients (95.1%). Thromboembolic (TE) complications occurred in 5/103 patients (4.9%), intraoperative rupture in 2/103 patients (1.9%), delayed aneurysm rupture in 1/103 patient (1.0%), and delayed hematoma occurred in 1/103 patient (1.0%). Six-months' mortality and morbidity rates were 1/102 (1.0%) and 2/102 (2.0%), respectively. CONCLUSIONS Aneurysm treatment with the FRED device is safe with low mortality (1.0%) and morbidity (2.0%). CLINICAL TRIAL REGISTRATION NCT02921698.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Intracranial Aneurysms with Flow Re-direction Endoluminal Device - A Single Centre Experience with Short-term Follow-up Results

PURPOSE A flow diverter (FD) is an effective treatment option for intracranial aneurysms. The Flow Re-direction Endoluminal Device (FRED) is a relatively new flow diverter with a unique dual-layer design. We report our experience and short-term results with the FRED. MATERIALS AND METHODS We did a retrospective review of all consecutive cases in which the FRED was used to treat intracranial a...

متن کامل

Cavernous carotid aneurysms in the era of flow diversion: a need to revisit treatment paradigms.

BACKGROUND AND PURPOSE Recent techniques of endoluminal reconstruction with flow-diverting stents have not been incorporated into treatment algorithms for cavernous carotid aneurysms. This study examines the authors' institutional experience and a systematic review of the literature for outcomes and complications using the Pipeline Embolization Device in unruptured cavernous carotid aneurysms. ...

متن کامل

New generation of Flow Diverter (surpass) for unruptured intracranial aneurysms: a prospective single-center study in 37 patients.

BACKGROUND AND PURPOSE In patients harboring intracranial aneurysms, the major goal in treatment is to prevent bleeding. A new generation of an endoluminal device (Surpass Flow Diverter [Surpass]) was developed to reconstruct parent artery and occlude the aneurysm. We present our clinical and angiographic single-center experience. METHODS Patients with a wide range of complex unruptured aneur...

متن کامل

Feasibility, procedural morbidity and mortality, and long-term follow-up of endovascular treatment of 321 unruptured aneurysms.

BACKGROUND AND PURPOSE The purpose of our study was to evaluate the technical feasibility, morbidity and mortality, and durability of occlusion of unruptured aneurysms treated with Guglielmi detachable coils (GDCs) with a long-term follow-up. MATERIALS AND METHODS Between January 1998 and January 2005, we treated 321 unruptured aneurysms with GDCs in 5 neuroradiologic institutions. During thi...

متن کامل

Surgical Protocol and Outcome of 60 Cases With Intracranial Aneurysm

Background and Aim: This study aimed to present the results of early and delayed operation on patients with ruptured brain aneurysms. In addition to comparing the results and rates of morbidity and mortality in the surgical procedure and identifying the effective factors, this study aimed to provide methods to improve the treatment of brain aneurysm. Methods and Materials/Patients: This was a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurointerventional surgery

دوره   شماره 

صفحات  -

تاریخ انتشار 2018