Evaluation of compressed lung CT image quality using quantitative analysis.

نویسندگان

  • S Yamamoto
  • T Johkoh
  • N Mihara
  • T Umeda
  • M Azuma
  • S Nakanishi
  • Y Narumi
  • H Naito
  • H Nakamura
چکیده

The goals of this study were (1) to evaluate the quality of compressed lung CT images obtained using high resolution CT (HRCT: 2 mm slice thickness) for degree of compression and conventional CT (10 mm slice thickness) images by using physical and subjective evaluations, and (2) to analyze the distortion of density distribution on lung CT images using histogram analysis for each compression ratio. The coding method was performed according to the Joint Photographic Experts Group (JPEG). We physically evaluated the quality of compressed lung CT images using the peak signal-to-noise ratio (PSNR) as given by the square root of the ratio of the peak value of the gray level squared to the mean square error (dB) and subjectively evaluated the CT images using the mean opinion score (MOS). The acceptable compression ratio for diagnosis was about 1:6 to 1:7 for conventional CT images and about 1:4 to 1:5 for HRCT images as determined by MOS. The PSNR corresponding to acceptable compression ratios was about 50 dB. The difference in density distribution between HRCT and conventional CT was statistically significant (Friedman test: p<0.02) in histogram analysis. Results suggested that, in comparison with conventional CT, a high compression ratio was not suitable for HRCT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Diagnosis of COVID-19 Disease Using Lung CT-scan Image Processing Techniques

Introduction: Today, several methods are used for detecting COVID-19 such as disease-related clinical symptoms, and more accurate diagnostic methods like lung CT-scan imaging. This study aimed to achieve an accurate diagnostic method for intelligent and automatic diagnosis of COVID-19 using lung CT-scan image processing techniques and utilize the results of this method as an accurate diagnostic...

متن کامل

Diagnosis of COVID-19 Disease Using Lung CT-scan Image Processing Techniques

Introduction: Today, several methods are used for detecting COVID-19 such as disease-related clinical symptoms, and more accurate diagnostic methods like lung CT-scan imaging. This study aimed to achieve an accurate diagnostic method for intelligent and automatic diagnosis of COVID-19 using lung CT-scan image processing techniques and utilize the results of this method as an accurate diagnostic...

متن کامل

Detection of lung cancer using CT images based on novel PSO clustering

Lung cancer is one of the most dangerous diseases that cause a large number of deaths. Early detection and analysis can be very helpful for successful treatment. Image segmentation plays a key role in the early detection and diagnosis of lung cancer. K-means algorithm and classic PSO clustering are the most common methods for segmentation that have poor outputs. In t...

متن کامل

Diagnostic Quality Evaluation of Compressed Medical Images for Telemedicine Applications

Many techniques for achieving data compression have been introduced. The fundamental goal of image data compression is to reduce the bit rate for transmission or storage while maintaining an acceptable reproduction quality, but it is natural to raise the question of how much an image can be compressed and still preserve sufficient information for a given telemedicine application. Evaluation of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation medicine

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 2001