[Prospective randomized trial comparing Discovisc versus Healon in phacoemulsification].
نویسندگان
چکیده
OBJECTIVE To compare the intraoperative behaviour of both, DisCoVisc and Healon used as viscoelastics in cataract surgery. METHOD We prospectively evaluated 35 patients with cataracts who underwent phacoemulsification and intraocular lens implantation. Patients were randomized into two groups. Group A included 17 patients in where Healon was used as a viscoelastic, whereas group B included 18 patients in where the viscoelastic used was DisCoVisc. After each procedure, the surgeon filled in a questionnaire describing the behaviour of the viscoelastic during the different stages of phacoemulsification. RESULTS DisCoVisc behaved as both cohesive and dispersive viscoelastic during capsulorrhexis, phacoemulsification and viscoelastic aspiration, whereas Healon acted as a cohesive substance during all surgical stages. DisCoVisc enabled better visualization and transparency during all the surgical stages and maintains the capsular bag better during the intraocular lens implantation. Viscoelastic aspiration was easier with Healon. CONCLUSIONS DisCoVisc is a new viscosurgical device with both cohesive and dispersive properties, which avoids using two different viscoelastics to improve the performance at different surgical stages. DisCoVisc has been shown to be more transparent and provides better anterior chamber maintenance when compared with Healon. Healon was more easily aspirated due to its cohesive character.
منابع مشابه
Safety, efficacy, and intraoperative characteristics of DisCoVisc and Healon ophthalmic viscosurgical devices for cataract surgery
PURPOSE To evaluate the safety and efficacy of DisCoVisc ophthalmic viscosurgical device (OVD, Alcon Laboratories, Inc) with respect to a comparator, Healon OVD (Advanced Medical Optics, Inc). PATIENTS AND METHODS In this prospective study, patients with cataracts were randomized to an OVD, and then received phacoemulsification and injection of an intraocular lens. After each surgery, unmaske...
متن کاملComparative Evaluation of Efficacy and Safety of Ophthalmic Viscosurgical Devices in Phacoemulsification
Background: Various ophthalmic viscosurgical devices (OVD) are used to perform phacoemulsification and other intraocular surgeries. We performed a study to compare the efficacy and safety of three ophthalmic viscosurgical devices that are routinely used in phacoemulsification. Methods: Fifty-six patients of immature senile cataract with hard nucleus (grade 3 and 4) who underwent phacoemulsifica...
متن کاملComparison of the effect of Healon vs. Viscoat on endothelial cell count after phacoemulsification and posterior chamber lens implantation.
To evaluate the protective effect of 1% sodium hyaluronate (Healon) vs. a mixture of 4% chondroitin sulfate and 3% sodium hyaluronate (Viscoat) on the central corneal endothelium during surgery, we prospectively examined 20 eyes of 20 patients who underwent clear corneal phacoemulsification and implantation of an intracapsular posterior chamber intraocular lens (PC-IOL) with either Healon (10 e...
متن کاملComparative evaluation of efficacy and safety of ophthalmic viscosurgical devices in phacoemulsification [ISRCTN34957881]
BACKGROUND Various ophthalmic viscosurgical devices (OVD) are used to perform phacoemulsification and other intraocular surgeries. We performed a study to compare the efficacy and safety of three ophthalmic viscosurgical devices that are routinely used in phacoemulsification. METHODS Fifty-six patients of immature senile cataract with hard nucleus (grade 3 and 4) who underwent phacoemulsifica...
متن کاملComparison of corneal endothelial cell loss during phacoemulsification using continuous anterior chamber infusion versus those using ophthalmic viscosurgical device: Randomized controlled trial
AIM We conducted this study to evaluate and compare corneal endothelial cell loss between phacoemulsification with continuous anterior chamber infusion using anterior chamber maintainer (ACM) and phacoemulsification using ophthalmic viscosurgical device (OVD). MATERIALS AND METHODS This was a prospective, randomized controlled trial. Fifty eyes of 47 patients of senile cataract undergoing pha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archivos de la Sociedad Espanola de Oftalmologia
دوره 82 8 شماره
صفحات -
تاریخ انتشار 2007