Motion-analysis and FEA can work together even though they are quite different. Motion-analysis software works with CAD assemblies. It starts by translating assembly mating conditions into corresponding kinematics pairs. It then calculates kinematics and dynamics data of the moving mechanism. Each component in mechanism, if viewed separately, is under balanced set of loads: joint reactions and inertial forces. Such isolated component behaves like structure, i.e. firmly supported object and FEA can deals with it. In short, motion analysis feeds FEA with data necessary to convert mechanism component into a structurea form digestible to FEA. These two numerical tools are applied on the above-knee prosthesis. The first, prosthesis assembly is made. Mating conditions are translated into kinematics pairs such as sliders, pin joints and fixed joints. Then, motion-analysis of prosthesis mechanism is done under subjected loads. The last, components in the foot assembly are remodeled, analyzed and optimized in FEA software, using reactions and inertial forces obtained from motion analysis.
منابع مشابه
Passive Controller Design for Swing Phase of a Single Axis Above-Knee Prosthesis
In this research we design a passive controller for an above knee prosthesis. The controller is a linear spring and damper for swing phase motion, parameters of which determined via optimization of adjustment of the prosthesis shank motion with a desired shank angle trajectory comes from experimental data. In this way, we exerted a certain thigh motion, hip movement included, into the system as...
متن کاملAn Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis
A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) of knee joint components are carried out to assess the feasibility of the design. The maximum stre...
متن کاملارزیابی کارایی گیت یک آمپوته همی پلویکتومی در حین راه رفتن با پروتز کانادین- گزارش موردی
Purpose: Hemipelvectomy amputation is a surgical procedure in which the lower limb and part of the pelvis are removed. Although few studies are available on the performance of individuals with hip disarticulation while walking, there is no study on gait analysis of hemipelvectomy subjects. Therefore, this study aimed to evaluate the gait and stability of an individual with hemipelvectomy amput...
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملA New Controlling Parameter in Design of Above Knee Prosthesis
In this paper after reviewing some previous studies, in order to optimize the above knee prosthesis, beside the inertial properties a new controlling parameter is informed. This controlling parameter makes the prosthesis able to act as a multi behavior system when the amputee is opposing to different environments. This active prosthesis with the new controlling parameter can simplify the contro...
متن کامل