Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent
نویسندگان
چکیده
منابع مشابه
Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial.
BACKGROUND There are no reports on a large-scale randomized trial exploring optimal dual antiplatelet therapy (DAPT) duration after biodegradable polymer sirolimus-eluting stent implantation. We sought to report the outcomes of a randomized substudy of the prospective Evaluate Safety and Effectiveness of the Tivoli DES and the Firebird DES for Treatment of Coronary Revascularization (I-LOVE-IT ...
متن کاملDual Antiplatelet Therapy Over 6 Months Increases the Risk of Bleeding after Biodegradable Polymer-Coated Sirolimus Eluting Stents Implantation: Insights from the CREATE Study
BACKGROUND The optimal duration of dual antiplatelet therapy (DAPT) after drug-eluting stent (DES) implantation remains controversial. The primary aim of our study was to evaluate the impact of optimal DAPT duration on bleeding events between 6 and 12 months after biodegradable polymer-coated DES implantation. The secondary aim is to determine the predictors and prognostic implications of bleed...
متن کاملSafety and efficacy of biodegradable polymer-coated sirolimus-eluting stents in "real-world" practice: 18-month clinical and 9-month angiographic outcomes.
OBJECTIVES This study sought to evaluate the safety and efficacy of a biodegradable polymer-coated sirolimus-eluting stent (Excel, JW Medical System, Weihai, China) with 6-month dual antiplatelet therapy in daily practice. BACKGROUND It has been hypothesized that persistent presence of polymer may compromise the safety of drug-eluting stents, and that therefore biodegradable polymer coatings ...
متن کاملUltrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.
BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...
متن کامل2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.
OBJECTIVES This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up. BACKGROUND BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegrada...