Pore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom.
نویسندگان
چکیده
Double pulsed-field gradient (d-PFG) MRI can provide quantitative maps of microstructural quantities and features within porous media and tissues. We propose and describe a novel MRI phantom, consisting of wafers of highly ordered glass capillary arrays (GCA), and its use to validate and calibrate a d-PFG MRI method to measure and map the local pore diameter. Specifically, we employ d-PFG Spin-Echo Filtered MRI in conjunction with a recently introduced theoretical framework, to estimate a mean pore diameter in each voxel within the imaging volume. This simulation scheme accounts for all diffusion and imaging gradients within the diffusion weighted MRI (DWI) sequence, and admits the violation of the short gradient pulse approximation. These diameter maps agree well with pore sizes measured using both optical microscopy and single PFG diffusion diffraction NMR spectroscopy using the same phantom. Pixel-by-pixel analysis shows that the local pore diameter can be mapped precisely and accurately within a specimen using d-PFG MRI.
منابع مشابه
Novel anisotropic MRI diffusion phantom
Diffusion MRI (DMRI) comprises a growing list of methods, and with that the need for a reliable and robust MRI phantom with which one can calibrate and validate them. In this study we developed a novel anisotropic diffusion MRI phantom and demonstrated its applicability by producing fractional anisotropy (FA) maps derived from DTI and average pore diameter maps using double Pulsed Field Gradien...
متن کاملMapping average axon diameters in porcine spinal cord white matter and rat corpus callosum using d-PFG MRI
Knowledge of microstructural features of nerve fascicles, such as their axon diameter, is crucial for understanding normal function in the central and peripheral nervous systems as well as assessing changes due to pathologies. In this study double-pulsed field gradient (d-PFG) filtered MRI was used to map the average axon diameter (AAD) in porcine spinal cord, which was then compared to AADs me...
متن کاملAnisotropic phantom to calibrate high-q diffusion MRI methods.
A silicon oil-filled glass capillary array is proposed as an anisotropic diffusion MRI phantom. Together with a computational/theoretical pipeline these provide a gold standard for calibrating and validating high-q diffusion MRI experiments. The phantom was used to test high angular resolution diffusion imaging (HARDI) and double pulsed-field gradient (d-PFG) MRI acquisition schemes. MRI-based ...
متن کاملMapping the pore size distribution of a glass microcapillary array phantom using d-PFG MRI
phantom using d-PFG MRI D. Benjamini M. E. Komlosh , P. J. Basser , U. Nevo STBB, PPITS, NICHD, NIH, Bethesda, MD; Department of Biomedical Engineering, The Iby and Aladar Fleischman Faculty of Engineering, Tel-Aviv University, Tel-Aviv, Israel. CNRM, USUHS, Bethesda, MD. Introduction: Noninvasive characterization of porous media is critical to many scientific and technical fields. Estimation ...
متن کاملNonparametric pore size distribution using d-PFG: comparison to s-PFG and migration to MRI.
Here we present the successful translation of a pore size distribution (PSD) estimation method from NMR to MRI. This approach is validated using a well-characterized MRI phantom consisting of stacked glass capillary arrays (GCA) having different diameters. By employing a double pulsed-field gradient (d-PFG) MRI sequence, this method overcomes several important theoretical and experimental limit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance
دوره 208 1 شماره
صفحات -
تاریخ انتشار 2011