Stability, Survival, and Tolerability of an Auditory Osseointegrated Implant for Bone Conduction Hearing: Long-Term Follow-Up of a Randomized Controlled Trial

نویسندگان

  • Christine A. den Besten
  • Joacim Stalfors
  • Stina Wigren
  • Johan Ivarsson Blechert
  • Mark Flynn
  • Måns Eeg-Olofsson
  • Rohini Aggarwal
  • Kevin Green
  • Rik C. Nelissen
  • Emmanuel A. M. Mylanus
  • Myrthe K. S. Hol
چکیده

OBJECTIVE To compare implant stability, survival, and soft tissue reactions for a novel (test) and previous generation (control) percutaneous auditory osseointegrated implant for bone conduction hearing at long-term follow-up of 5 years. STUDY DESIGN Single follow-up visit of a previously completed multicenter, randomized, controlled trial. PATIENTS Fifty-seven of the 77 participants of a completed randomized controlled trial on a new auditory osseointegrated implant underwent a single follow-up visit 5 years after implantation, which comprised implant stability measurements and collection of Holgers scores. Additionally, implant survival was recorded for all 77 patients from the original trial. RESULTS The test implant showed significantly higher implant stability quotient (ISQ) values compared with the control implant throughout the 5-year follow-up. Mean area under the curve of ISQ high from baseline to 5 years was 71.6 (standard deviation [SD] ±2.0) and 66.7 (SD ±3.4) for the test and control implant, respectively (p < 0.0001). For both implants, the mean ISQ value recorded at 5 years was higher compared with implantation (test group +2.03 [SD ±2.55, within group p < 0.0001] and control group +2.25 [SD ±4.95, within group p = 0.12]). No difference was noticed in increase from baseline between groups (p = 0.64). Furthermore, evaluation of soft tissue reactions continued to show superiority of the test implant. At the 5-year follow-up visit, one patient (2.5%) presented with a Holgers grade 2 in the test group, compared with four patients (23.5%) in the control group (p = 0.048); no patient presented with more severe soft tissue reactions. Excluding explantations, the survival rate was 95.8% for the test group and 95.0% for the control group. The corresponding rates including explantations were 93.9 and 90.0%. CONCLUSION The test implant showed superiority in terms of higher mean ISQ values and less adverse soft tissue reactions, both at the single 5-year follow-up visit and during the complete follow-up. In addition, both implants showed an equally high implant survival.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability, survival, and tolerability of a 4.5-mm-wide bone-anchored hearing implant: 6-month data from a randomized controlled clinical trial

The objective of this study was to compare the stability, survival, and tolerability of 2 percutaneous osseointegrated titanium implants for bone conduction hearing: a 4.5-mm diameter implant (test) and a 3.75-mm diameter implant (control). Fifty-seven adult patients were included in this randomized controlled clinical trial. Sixty implants were allocated in a 2:1 (test–control) ratio. Follow-u...

متن کامل

Improving sound localization after cochlear implantation and auditory training for the management of single-sided deafness.

OBJECTIVE To report a successful case of cochlear implantation and auditory training for the improvement of sound localization in a patient with single-sided deafness. STUDY DESIGN Case report and literature review. SETTING Tertiary referral otology practice. PATIENT Fifty-seven-year-old man receiving cochlear implantation after 8 years of unilateral sensorineural hearing loss. INTERVEN...

متن کامل

Complications and parent satisfaction in pediatric osseointegrated bone-conduction hearing implants.

OBJECTIVE To assess long-term complication rate and parental satisfaction of osseointegrated bone conduction hearing implants (OBCHIs). STUDY DESIGN Retrospective chart review of children undergoing OBCHIs. METHODS A retrospective chart review of children undergoing OBCHIs for the treatment of conductive, mixed, and single-sided sensorineural hearing loss in children. RESULTS Forty-five s...

متن کامل

Comparison of the Pediatric Cochlear Implantation Using Round Window and Cochleostomy

Introduction: Cochlear implantation (CI) is now regarded as a standard treatment for children with severe to profound sensor neural hearing loss. This study aimed to compare the efficacy of the round window approach (RWA) and standard cochleostomy approach (SCA) in the preservation of residual hearing after CI in pediatric patients. Materials and Methods: This double-blind ran...

متن کامل

Early Diagnosis and Intervention for Hearing Loss in Newborns Discharged from Intensive Care Units: a Four-year Follow-up Study in North of Iran

Background Hearing loss is the most common congenital disorder the incidence of which is further increased in the presence of risk factors for hearing loss among newborns admitted to the neonatal intensive care unit (NICU). The aim of this study was early diagnosis and intervention for hearing loss in newborns discharged from NICU. Materials and Methods This prospective cohort study was conduct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2016