Quantification of the distribution of blood flow pressure with postures
نویسندگان
چکیده
At a different angle, this study analyzed the contour chart of blood flow pressure, extreme pressure and its position to quantify DBFP in thirteen different postures with gravity considered or not (G ≠ 0 or G = 0). The aim was to determine the suitable body positions, in which the postural model of a single vessel could be simplified to two-dimensional (2D) symmetrical one while only considering such factors as posture and gravity. Computational fluid dynamic simulations were performed. Numerical results demonstrated that the DBFP showed 2D axisymmetry at ±90 ̊ and three-dimensional (3D) asymmetry at any other posture with G ≠ 0, and 2D axisymmetrical one at any posture with G = 0. Therefore, modeling a vessel as a 2D model is feasible in space and at ±90 ̊ posture on earth. In addition, the maximum pressure occurred between the inlet and the middle of the vessel, and its position variation mainly happened in the range of 0 ̊ 15 ̊. For a single vessel, this study provides the first theoretical evidence for cardiovascular modeling in microgravity and may help guide the researchers in designing defense devices for astronauts or patients clinically.
منابع مشابه
Numerical Simulation of Blood Flow Mixed with Magnetic Nanoparticles under the Influence of AC and DC Magnetic Field
Nanoparticles combined with magnetic fields are one of the most important research areas in the field of biomedical engineering. Direct Current (DC) magnetic and Alternative Current (AC) magnetic fields are often used for controlling nanoparticles. It is also used for hyperthermia treatment. The purpose of the current study is to investigate the effect of DC and AC magnetic field on nanoparticl...
متن کاملAn advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries
Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...
متن کاملDesigning and Constructing Blood Flow Monitoring System to Predict Pressure Ulcers on Heel
Background: A pressure ulcer is a complication related to the need for the care and treatment of primarily disabled and elderly people. With the decrease of the blood flow caused by the pressure loaded, ulcers are formed and the tissue will be wasted with the passage of time.Objective the aim of this study was to construct blood flow monitoring system on the heel tissue which was under external...
متن کاملComputational simulations of nanoparticle transport in a three-dimensional capillary network
Objective(s): Multifunctional nanomedicine is the new generation of medicine, which is remarkably promising and associated with the minimum toxicity of targeted therapy. Distribution and transport of nanoparticles (NPs) in the blood flow are essential to the evaluation of delivery efficacy. Materials and Methods: In the present study, we initially designed a phantom based on Murray’s mini...
متن کاملThermal simulation of two-phase flow in under-balanced drilling operation with oil and gas production
The accurate prediction of wellbore temperature distribution helps to accurately estimate well pressure profile and bottom-hole pressure (BHP) which is important in the under-balanced drilling (UBD) operation. In this paper effect of temperature variation due to heat transfer of drilling fluid with the formation and also oil and gas production from the reservoir into the annulus in under-balanc...
متن کامل