High resolution carotid black-blood 3T MR with parallel imaging and dedicated 4-channel surface coils

نویسندگان

  • Tobias Saam
  • Jose G Raya
  • Clemens C Cyran
  • Katja Bochmann
  • Georgios Meimarakis
  • Olaf Dietrich
  • Dirk A Clevert
  • Ute Frey
  • Chun Yuan
  • Thomas S Hatsukami
  • Abe Werf
  • Maximilian F Reiser
  • Konstantin Nikolaou
چکیده

BACKGROUND Most of the carotid plaque MR studies have been performed using black-blood protocols at 1.5 T without parallel imaging techniques. The purpose of this study was to evaluate a multi-sequence, black-blood MR protocol using parallel imaging and a dedicated 4-channel surface coil for vessel wall imaging of the carotid arteries at 3 T. MATERIALS AND METHODS 14 healthy volunteers and 14 patients with intimal thickening as proven by duplex ultrasound had their carotid arteries imaged at 3 T using a multi-sequence protocol (time-of-flight MR angiography, pre-contrast T1w-, PDw- and T2w sequences in the volunteers, additional post-contrast T1w- and dynamic contrast enhanced sequences in patients). To assess intrascan reproducibility, 10 volunteers were scanned twice within 2 weeks. RESULTS Intrascan reproducibility for quantitative measurements of lumen, wall and outer wall areas was excellent with intraclass correlation coefficients >0.98 and measurement errors of 1.5%, 4.5% and 1.9%, respectively. Patients had larger wall areas than volunteers in both common carotid and internal carotid arteries and smaller lumen areas in internal carotid arteries (p < 0.001). Positive correlations were found between wall area and cardiovascular risk factors such as age, hypertension, coronary heart disease and hypercholesterolemia (Spearman's r = 0.45-0.76, p < 0.05). No significant correlations were found between wall area and body mass index, gender, diabetes or a family history of cardiovascular disease. CONCLUSION The findings of this study indicate that high resolution carotid black-blood 3 T MR with parallel imaging is a fast, reproducible and robust method to assess carotid atherosclerotic plaque in vivo and this method is ready to be used in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 16 Channel Radio Frequency Anterior Neck Coil for Imaging of the Cervical Carotid Bifurcation

Introduction Disease of the cervical carotid artery occurs primarily in the region of the cervical carotid bifurcation and is a major source of embolic stroke. Although MRI may be the best method for imaging and characterizing the individual risk of the disease, imaging the disease is hampered by the small size of the plaque morphology, the variable position and depth of the artery in many subj...

متن کامل

Cardiac-gated local coil MR imaging of the carotid neck bifurcation.

The value of duplex Doppler sonography as a noninvasive technique for evaluating the carotid neck vessels has been well documented [1-4]. The sensitivity and specificity of duplex Doppler sonography in the detection of high-grade stenosis (greater than 80%) approximates 90% [1] . However, duplex Doppler sonography has several limitations. Plaque ulceration cannot be detected reliably, even with...

متن کامل

High-Resolution 3T MR Imaging of the Triangular Fibrocartilage Complex

This study is intended as a review of 3Tesla (T) magnetic resonance (MR) imaging of the triangular fibrocartilage complex (TFCC). The recent advances in MR imaging, which includes high field strength magnets, multi-channel coils, and isotropic 3-dimensional (3D) sequences have enabled the visualization of precise TFCC anatomy with high spatial and contrast resolution. In addition to the routine...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Cardiovascular Magnetic Resonance

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2009