Dose heterogeneity may not affect the neointimal proliferation after gamma radiation for in-stent restenosis: a volumetric intravascular ultrasound dosimetric study.

نویسندگان

  • Akiko Maehara
  • Neil S Patel
  • Louis B Harrison
  • Neil J Weissman
  • Anh B Bui
  • Han-Soo Kim
  • Andrew E Ajani
  • Marco T Castagna
  • Taya L McMillan
  • Nathan Yang
  • Rosanna Chan
  • Julliana Pisch
  • Harry Quan
  • Sou-Tung Chiu-Tsao
  • Ron Waksman
  • Gary S Mintz
چکیده

OBJECTIVES The goal of this study was to use serial (postirradiation and follow-up) volumetric intravascular ultrasound (IVUS): 1) to evaluate the actual distribution of gamma radiation in human in-stent restenosis (ISR) lesions, and 2) to analyze the relationship between neointimal regrowth and the delivered radiation dose. BACKGROUND The relationship between the neointimal regrowth and delivered dose during the treatment of ISR remains unknown. METHODS We analyzed 20 actively (gamma emitter) treated, native artery ISR patients from the Washington Radiation for In-Stent restenosis Trial (WRIST) that met the following criteria: on both postirradiation and six-month follow-up IVUS imaging, > or =80% of the external elastic membrane circumference could be identified throughout the treated length including the lesion and proximal and distal reference segments. Intravascular ultrasound images were digitized every 1 mm. Proximal and distal reference and stented segment luminal and adventitial contours were imported and reconstructed. The source was placed circumferentially at the site of the IVUS catheter and longitudinally according to the relationship between the radioactive seeds and stent edges. Using Monte Carlo simulations, dose volume histograms for the adventitia and intima were calculated. The relationship between the neointimal regrowth and calculated doses were evaluated. RESULTS There was large dose heterogeneity at both the intimal and adventitial levels. Most of the sites (93%) received >4 Gy at the adventitia, and all of the sites received >4 Gy at the intima. There was no relationship between neointimal regrowth and radiation dose. CONCLUSIONS Although there may be large dose heterogeneity, gamma irradiation (using a fixed dose prescription) appears to deliver a sufficient dose to prevent neointimal regrowth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delivered Dose and Vascular Response After -Radiation for In-Stent Restenosis Retrospective Dosimetry and Volumetric Intravascular Ultrasound Analysis

Background—Observations from previous intracoronary radiation therapy trials noted a considerable discrepancy between the prescribed radiation dose and the dose actually delivered. The aims of this study were to investigate the effect of actual delivered dose on vascular changes and to test the appropriateness of the current dose prescription. Methods and Results—Serial volumetric intravascular...

متن کامل

Delivered dose and vascular response after beta-radiation for in-stent restenosis: retrospective dosimetry and volumetric intravascular ultrasound analysis.

BACKGROUND Observations from previous intracoronary radiation therapy trials noted a considerable discrepancy between the prescribed radiation dose and the dose actually delivered. The aims of this study were to investigate the effect of actual delivered dose on vascular changes and to test the appropriateness of the current dose prescription. METHODS AND RESULTS Serial volumetric intravascul...

متن کامل

Paclitaxel coating reduces in-stent intimal hyperplasia in human coronary arteries: a serial volumetric intravascular ultrasound analysis from the Asian Paclitaxel-Eluting Stent Clinical Trial (ASPECT).

BACKGROUND The aim of this study was to use serial volumetric intravascular ultrasound (IVUS) to evaluate the effect of a paclitaxel coating on in-stent intimal hyperplasia (IH). METHODS AND RESULTS Patients were randomized to placebo (bare metal stents) or 1 of 2 doses of paclitaxel (low dose: 1.28 microg/mm2; high dose: 3.10 microg/mm2). Complete post-stent implantation and follow-up IVUS w...

متن کامل

The pattern of restenosis and vascular remodelling after cold-end radioactive stent implantation.

BACKGROUND Edge restenosis is a major problem after radioactive stenting. The cold-end stent has a radioactive mid-segment (15.9 mm) and non-radioactive proximal and distal 5.7 mm segments. Conceptually this may negate the impact of negative vascular remodelling at the edge of the radiation. METHOD AND RESULTS ECG-gated intravascular ultrasound with three-dimensional reconstruction was perfor...

متن کامل

Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study.

BACKGROUND Restenosis remains an important limitation of interventional cardiology. Therefore, we aimed to determine the safety and efficacy of sirolimus (a cell-cycle inhibitor)-coated BX Velocity stents. METHODS AND RESULTS Thirty patients with angina pectoris were electively treated with 2 different formulations of sirolimus-coated stents (slow release [SR], n=15, and fast release [FR], n=...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 39 12  شماره 

صفحات  -

تاریخ انتشار 2002