Calibration of laboratory aeration apparatus.
نویسندگان
چکیده
Aeration of some sort is frequently provided during laboratory cultivation of bacteria. Since metabolic responses and the nature of fermentation products may depend upon the amount of available oxygen (Pirt, 1957), it is important to have some adequate measure of this variable. Finn (1954) has pointed out that gassing rates alone are without significance; it is necessary to determine the rate at which oxygen actually goes into solution and becomes available to the cells during growth in a given culture apparatus. Of several methods available for measuring such oxygen absorption rates (OAR), the sulfite oxidation procedure (Cooper et al., 1944) is convenient and requires little equipment. While reports have been made outlining sulfite procedures for determining oxygen absorption rates in industrial reactors (Cooper et al., 1944) and laboratory shake flasks (Corman et al., 1957), many investigators make use of small volume culture apparatus employing a constant flow air pump or a laboratory compressed air line. Although such work may involve aerating culture volumes as small as 5 or 10 ml, accurate calibration of the apparatus for OAR is still essential.
منابع مشابه
Enhancement of oxygen transfer efficiency in diffused aeration systems using liquid-film-forming apparatus.
Surface transfer and bubble transfer both contribute significantly to oxygen transfer in a diffused aeration system. In the present study, liquid-film-forming apparatus is successfully developed on a laboratory scale to improve considerably the surface transfer via the unique liquid film transfer technique. The experimental results show that the volumetric mass transfer coefficient for liquid-f...
متن کاملA melting-point-of gallium apparatus for thermometer calibration.
We have investigated the equilibrium melting point of gallium as a temperature fixed-point at which to calibrate small thermistor thermometers, such as those used to measure temperature in enzyme reaction analysis and other temperature-dependent biological assays. We have determined that the melting temperature of "6N" (99.999% pure) gallium is 29.770 +/- 0.002 degrees C, and that the constant-...
متن کاملClosed-system Apparatus for Aeration-diffusion: Application to Determination of Blood Ammonia.
An apparatus is proposed primarily for comparison with other methods for determination of “blood ammonia,” and studies of involved factors. It employs the aeration-diffusion method of Van Slyke and Cullen, but in a closed system which avoids loss of ammonia and contamination with ammonia from the outside. Incomplete liberation of ammonia is avoided by the use of a moving thin film ever renewed ...
متن کاملChemically defined media supplemented with precursors for synnematin production.
result from other techniques, such as those requiring aeration of cultures. The exhaust air from such operationls must be sterilized and the most reliable means of doing this is incineration. The 1 cfm capacity of the incinerator described above is sufficient for mnost laboratory scale operations. If provision is made for cooling the exit air, the apparatus may be employed as a source of steril...
متن کاملLaboratory Apparatus to Evaluate Microalgae Production
The application of microalgae for energy purposes and CO2 biomitigation continues to present a number of challenges, including the optimization of culture conditions. The application of experimental designs for microalgae cultivation is difficult, since experiments involving such microorganisms generally last days or weeks. This work proposes a multipurpose laboratory apparatus for the optimiza...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied microbiology
دوره 7 2 شماره
صفحات -
تاریخ انتشار 1959