Characterization of particulate matter size distributions and indoor concentrations from kerosene and diesel lamps.

نویسندگان

  • J Apple
  • R Vicente
  • A Yarberry
  • N Lohse
  • E Mills
  • A Jacobson
  • D Poppendieck
چکیده

UNLABELLED Over one-quarter of the world's population relies on fuel-based lighting. Kerosene lamps are often located in close proximity to users, potentially increasing the risk for respiratory illnesses and lung cancer. Particulate matter concentrations resulting from cook stoves have been extensively studied in the literature. However, characterization of particulate concentrations from fuel-based lighting has received minimal attention. This research demonstrates that vendors who use a single simple wick lamp in high-air-exchange market kiosks will likely be exposed to PM(2.5) concentrations that are an order of magnitude greater than ambient health guidelines. Using a hurricane lamp will reduce exposure to PM(2.5) and PM(10) concentrations by an order of magnitude compared to using a simple wick lamp. Vendors using a single hurricane or pressure lamp may not exceed health standards or guidelines for PM(2.5) and PM(10), but will be exposed to elevated 0.02-0.3 μm particle concentrations. Vendors who change from fuel-based lighting to electric lighting technology for enhanced illumination will likely gain the ancillary health benefit of reduced particulate matter exposure. Vendors exposed only to ambient and fuel-based lighting particulate matter would see over an 80% reduction in inhaled PM(2.5) mass if they switched from a simple wick lamp to an electric lighting technology. PRACTICAL IMPLICATIONS Changing lighting technologies to achieve increased efficiency and energy service levels can provide ancillary health benefits. The cheapest, crudest kerosene lamps emit the largest amounts of PM(2.5). Improving affordability and access to better lighting options (hurricane or pressure lamps and lighting using grid or off-grid electricity) can deliver health benefits for a large fraction of the world's population, while reducing the economic and environmental burden of the current fuel-based lighting technologies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scaling Air Quality Effects from Alternative Jet Fuel in Aircraft and Ground Support Equipment

Many of the nation's largest airports, including Los Angeles International Airport, the Hartsfield-Jackson Atlanta International Airport, Chicago O'Hare International Airport and Washington Dulles International Airport are located within areas designated by the EPA as having ambient particulate matter concentrations that exceed National Ambient Air Quality standards. When inhaled, fine particul...

متن کامل

Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.

An intensive particle monitoring study was conducted in homes in the Boston, Massachusetts, area during the winter and summer of 1996 in an effort to characterize sources of indoor particles. As part of this study, continuous particle size and mass concentration data were collected in four single-family homes, with each home monitored for one or two 6-day periods. Additionally, housing activity...

متن کامل

Associations between ambient, personal, and indoor exposure to fine particulate matter constituents in Dutch and Finnish panels of cardiovascular patients.

AIMS To assess the relation between ambient, indoor, and personal levels of PM2.5 and its elemental composition for elderly subjects with cardiovascular disease. METHODS In the framework of a European Union funded study, panel studies were conducted in Amsterdam, the Netherlands and Helsinki, Finland. Outdoor PM2.5 concentrations were measured at a fixed site. Each subject's indoor and person...

متن کامل

Effects of diesel exhaust aftertreatment devices on concentrations and size distribution of aerosols in underground mine air.

Three types of uncatalyzed diesel particulate filter (DPF) systems, three types of high-temperature disposable filter elements (DFEs), and one diesel oxidation catalytic converter (DOC) were evaluated in underground mine conditions for their effects on the concentrations and size distributions of diesel aerosols. Those effects were compared with the effects of a standard muffler. The experiment...

متن کامل

Particle concentrations in urban microenvironments.

Although ambient particulate matter has been associated with a range of health outcomes, the health risks for individuals depend in part on their daily activities. Information about particle mass concentrations and size distributions in indoor and outdoor microenvironments can help identify high-risk individuals and the significant contributors to personal exposure. To address these issues in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 2010