Familiarization, reliability, and comparability of a 40-m maximal shuttle run test.
نویسندگان
چکیده
The aims of this study were to examine familiarization and reliability associated with a 40-m maximal shuttle run test (40-m MST), and to compare performance measures from the test with those of a typical unidirectional multiple sprint running test (UMSRT). 12 men and 4 women completed four trials of the 40-m MST (8 × 40-m; 20 s rest periods) followed by one trial of a UMSRT (12 × 30-m; repeated every 35 s); with seven days between trials. All trials were conducted indoors and performance times were recorded via twin-beam photocells. Significant between-trial differences in mean 40-m MST times were indicative of learning effects between trials 1 and 2. Test-retest reliability across the remaining trials as determined by coefficient of variation (CV) and intraclass correlation coefficient (ICC) revealed: a) very good reliability for measures of fastest and mean shuttle time (CV = 1.1 - 1.3%; ICC = 0.91 - 0.92); b) good reliability for measures of blood lactate (CV = 10.1 - 23.9%; ICC = 0.74 - 0.82) and ratings of perceived exertion (CV = 5.3 - 7.6%; ICC = 0.79 - 0.84); and c) poor reliability for measures of fatigue (CV = 38.7%; ICC = 0.59). Comparisons between performance indices of the 40-m MST and the UMSRT revealed significant correlations between all measures, except pre-test blood lactate concentration (r = 0. 47). Whilst the 40-m MST does not appear to provide more information than can be gleaned from a typical UMSRT, following the completion of a familiarization trial, the 40-m MST provides an alternative and, except for fatigue measures, reliable means of evaluating repeated sprint ability. Key pointsTests of multiple sprint performance are a popular means of evaluating repeated sprint ability.Multiple sprint tests incorporating changes of direction may be more ecologically valid than unidirectional protocols.The 40-m maximal shuttle run test is a reliable way of evaluating repeated sprint ability following the completion of one familiarization trial.The 40-m maximal shuttle run test shows no clear advantage over a standard unidirectional multiple sprint test.
منابع مشابه
The interval shuttle run test for intermittent sport players: evaluation of reliability.
The reliability of the interval shuttle run test (ISRT) as a submaximal and maximal field test to measure intermittent endurance capacity was examined. During the ISRT, participants alternately run for 30 seconds and walk for 15 seconds. The running speed is increased from 10 km.h(-1) every 90 seconds until exhaustion. Within a 2-week period, 17 intermittent sport players (i.e., 10 men and 7 wo...
متن کاملA progressive shuttle run test to estimate maximal oxygen uptake.
The purpose of the present study was to examine the validity of using a 20 m progressive shuttle run test to estimate maximal oxygen uptake. Running ability was described as the final level attained on the shuttle run test and as time on a 5 km run. Maximal oxygen uptake (VO2 max) was determined directly for seventy-four volunteers (36 men, 38 women) who also completed the shuttle run test. Max...
متن کاملCross Validation of the 20-m Shuttle Run Test for Children and Adolescents With Mental Retardation
We cross validated the 20-m shuttle run test of aerobic capacity in children and adolescents with mild and moderate mental retardation @lR) using the population specific formula of Femhall et al. (1998). Nine boys and 8 girls (age = 13.7 yr) completed a maximal treadmill protocol (measured .\iOtFk) and a 20-m shuttle run (predicted ~ 0 , ~ ~ ) . The measured peak oxygen consumption ( ~ 0 ~ ~ ) ...
متن کاملReliability and validity of data for 2 newly developed shuttle run tests in children with cerebral palsy.
BACKGROUND AND PURPOSE The purpose of this study was to examine the reliability and validity of data obtained with 2 newly developed shuttle run tests (SRT-I and SRT-II) to measure aerobic power in children with cerebral palsy (CP) who were classified at level I or II on the Gross Motor Function Classification System (GMFCS). The SRT-I was developed for children at GMFCS level I, and the SRT-II...
متن کاملReliability of the parameters of the power-duration relationship using maximal effort time-trials under laboratory conditions
The purpose of this study was to assess the reliability of critical power (CP) and the total amount of work accomplished above CP (W´) across repeated tests using ecologically valid maximal effort time-trials (TT) under laboratory conditions. After an initial incremental exercise test, ten well-trained male triathletes (age: 28.5 ± 4.7 years; body mass: 73.3 ± 7.9 kg; height: 1.80 ± 0.07 m; max...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 8 1 شماره
صفحات -
تاریخ انتشار 2009