Comparative evaluation of bite force analytical study following mandibular osteosysthesis using three-dimensional and conventional locking miniplates
نویسندگان
چکیده
AIMS AND OBJECTIVES The aim is to study the effectiveness of 2 mm three-dimensional (3D) titanium miniplates and 2 mm conventional titanium miniplates in osteosynthesis of mandibular fractures by comparing the change in bite force. METHODOLOGY The study comprised forty patients of age group 20-40 years, weighing 55-75 kg having mandibular fractures. Patients were randomly divided into two equal groups In Group A, twenty patients underwent osteosynthesis using 3D titanium miniplates (2.0 mm system), whereas in Group B, twenty patients underwent osteosynthesis using conventional titanium miniplates (2.0 mm system). After fixation of fracture segments with miniplates, the patients were assessed on the basis of evaluation of bite force at incisor, right molar and left molar region after 1, 3, 6 , and 8 weeks. Comparison of change in bite force was done between Group A and Group B at different follow-ups at incisor, right molar, and left molar. RESULTS Bite force recordings showed increasing values at subsequent follow-ups, corresponding to the healing of the fracture in both groups. At follow-up III (6 weeks) and IV (8 weeks), bite force values reached near to those in healthy individuals. A significant difference was observed in change in bite force of Group A and Group B at incisor left molar and right molar on subsequent followups. 3D titanium miniplate requires less surgical exposure of the underlying fracture site, with a minimal traction of the surrounding soft tissue. INTERPRETATION AND CONCLUSION 3D miniplates in mandibular fractures are efficacious enough to bear masticatory loads during the osteosynthesis of fractures. It gives the advantage of greater stability, increased bite force, reduced implant material, and 3D stability.
منابع مشابه
A comparative study on evaluation of role of 1.5 mm microplates and 2.0 mm standard miniplates in management of mandibular fractures using bite force as indicator of recommendation
AIMS AND OBJECTIVES To compare the maximum voluntary bite force generated at different periods during mandibular fracture healing using miniplates and microplates as means of rigid internal fixation. MATERIALS AND METHODS Maximum voluntary bite force was recorded in healthy young individuals of different age group from either gender. Patients suffering from symphyseal and parasymphyseal and b...
متن کامل3-D locking titanium miniplates in management of mandibular fracture: A prospective clinical study
Purpose: The aim of this follow up clinical study was to evaluate the effectiveness of 2mm, 3-dimentional locking titanium miniplates. Patients and Method: A prospective randomized clinical trial was carried out on 10 patients with mandibular fractures. The patients were evaluated for the operating time, clinical assessment of mobility after fixation, occlusion, adequacy of reduction on postope...
متن کامل3-D locking titanium miniplates in management of mandibular fracture: A prospective clinical study
Purpose: The aim of this follow up clinical study was to evaluate the effectiveness of 2mm, 3-dimentional locking titanium miniplates. Patients and Method: A prospective randomized clinical trial was carried out on 10 patients with mandibular fractures. The patients were evaluated for the operating time, clinical assessment of mobility after fixation, occlusion, adequacy of reduction on postope...
متن کاملThree-dimensional finite element analysis of mechanical stress in symphyseal fractured human mandible reduced with miniplates during mastication.
PURPOSE In this study we tried to analyze the stress distribution in a symphyseal fractured human mandible reduced by 2 different methods--reduction with 1 miniplate or with 2 miniplates--by using finite element (FE) analysis, and then compared the results with an intact mandible. MATERIALS AND METHODS Three-dimensional FE models of an intact mandible and symphyseal fractured mandibles reduce...
متن کاملComparison of Locking Titanium Miniplates and Conventional Titanium Miniplates in Treatment of Mandibular Fractures
The goal of fracture management is to restore proper function by union of the fractured segments and restoring the strength, contour defects that might have happened at the time of injury, and controlling infection at the fracture site. 1 The present study were to evaluate and compare the treatment outcome between 2D locking titanium miniplates and conventional 2D miniplates for symphysis, para...
متن کامل