Variability in Measures of Exhaled Breath Na+, Influence of Pulmonary Blood Flow and Salivary Na+

نویسندگان

  • Courtney M. Wheatley
  • Nicholas A. Cassuto
  • William T. Foxx-Lupo
  • Eric M. Snyder
چکیده

The assessment of inflammatory markers and ions in exhaled breath condensate (EBC) is being utilized more frequently in diseases such as asthma and cystic fibrosis with marked variability in EBC measures, including those of exhaled Na(+). We sought to determine if variability in exhaled Na(+) was due to differences in pulmonary blood flow (PBF) or Na(+) in the mouth (salivary Na(+)). We measured exhaled Na(+) three times with coinciding sampling of salivary Na(+) and assessment of PBF (using acetylene rebreathing) in 13 healthy subjects (54% female, age = 27 ± 7 yrs., ht. = 172 ± 10 cm, wt. = 70 ± 21 kg, BMI = 22 ± 7 kg/m(2) mean ± SD). Exhaled Na(+) averaged 2.7 ± 1.2 mmol/l, and salivary Na(+) averaged 5.51 ± 4.58 mmol/l. The coefficients of variation across all three measures in all 13 subjects averaged 30% for exhaled Na(+) and 83% for salivary Na(+), within subjects the variability across the three measures averaged 30% for exhaled Na(+) and 38% for salivary Na(+). Across all three measures in all 13 subjects the relationship between PBF and exhaled Na(+) averaged 0.027 (P = 0.87), and the relationship between salivary Na(+) and exhaled Na(+) concentrations averaged 0.59 (P = 0.001). Also, we sought to determine the relationship between exhaled Na(+) and serum Na(+) in an addition 20 subjects. There was a moderate and significant relationship between serum Na(+) and exhaled Na(+) (r = 0.37, P = 0.04). These findings suggest there that the variability in exhaled Na(+) is caused, at least in part, by droplet formation from within the mouth as turbulent air passes through and that there is a flux of ions from the pulmonary blood into the airways.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Expiratory flow rate, breath hold and anatomic dead space influence electronic nose ability to detect lung cancer

BACKGROUND Electronic noses are composites of nanosensor arrays. Numerous studies showed their potential to detect lung cancer from breath samples by analysing exhaled volatile compound pattern ("breathprint"). Expiratory flow rate, breath hold and inclusion of anatomic dead space may influence the exhaled levels of some volatile compounds; however it has not been fully addressed how these fact...

متن کامل

The Influence of Pulmonary Function Testing on the Management of Asthma in Children

weeks with noninvasive measures of airway inflammation including exhaled nitric oxide (eNO), sputum induction with bronchial hyperreactivity testing, and exhaled breath condensate. Physicians who were unaware of the results of inflammatory measures made reductions in the steroid dose on the basis of clinical assessment and spirometry. Multiple logistic-regression models were used to determine t...

متن کامل

Reproducibility of exhaled breath condensate pH in chronic obstructive pulmonary disease.

Increasingly, exhaled breath condensate (EBC) is being used to sample airway fluid from the lower respiratory tract. EBC pH may be a biomarker of airway inflammation in chronic obstructive pulmonary disease (COPD). In this study, the reproducibility of EBC pH in COPD was investigated. A total of 36 COPD patients and 12 healthy nonsmoking subjects participated in several investigations: duration...

متن کامل

تجزیه آلکان‌ها و آلدئیدهای درون‌زاد در هوای بازدم شاغلین در مواجهه با غبار حاوی سیلیس

 Background & Objectives : Silica is one of the most air pollutant in workplaces which long-term occupational exposure to silica is associated with an increased risk for respiratory diseases such as silicosis. Silicosis is an oxidative stress related disease and can lead to the development of lung cancer. This study aims to analysis of endogenous alkanes and aldehydes in the exhaled breath...

متن کامل

A physiological-social score for triaging of pandemic influenza patients.

In summary, argon deaeration decreases the concentration and the variability of exhaled breath condensate partial pressure of CO2, but there is always some remaining CO2 that may still be a confounding factor in pH assessment. CO2 content has a marked influence on exhaled breath condensate pH and, since exhaled breath condensate partial pressure of CO2 varies even after deaeration, it leaves so...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2010