Comparison of clinical non-commercial tools for automated quantification of myocardial blood flow using oxygen-15-labelled water PET/CT.

نویسندگان

  • Hendrik J Harms
  • Sergey V Nesterov
  • Chunlei Han
  • Ibrahim Danad
  • Remigio Leonora
  • Pieter G Raijmakers
  • Adriaan A Lammertsma
  • Juhani Knuuti
  • Paul Knaapen
چکیده

AIMS Absolute quantification of myocardial blood flow (MBF) with (15)O-water cardiac positron emission tomography (PET)/CT has recently demonstrated to hold promising diagnostic value for the detection of coronary artery disease (CAD). However, methodological differences in utilized analysis software packages (SP) could affect generated MBF values, potentially prohibiting widespread clinical applicability of obtained normal thresholds. The aim of this study was to compare two validated non-commercial SP, Carimas and Cardiac VUer, for the quantification of MBF using (15)O-water PET. METHODS AND RESULTS One hundred patients with intermediate likelihood of CAD and scanned in academic centres in Amsterdam (n = 50) and Turku (n = 50) were included in the study. Patients underwent a (15)O-water PET/CT scan during rest and vasodilator stress based on clinical indications. A single observer, blinded from clinical results and with no prior experience in either SP, analysed all patients twice with both SP. Reproducibility of each SP was assessed using intraclass correlation coefficients (ICC). Intersoftware agreement was assessed using paired t-tests and linear regression. ICC was excellent for each SP for both global and regional MBF (ICC >0.90). Global MBF was comparable between Carimas and Cardiac VUer during rest (1.02 ± 0.28 vs. 0.99 ± 0.23 mL min(-1)g(-1), respectively, P = 0.07), and slightly higher for Carimas during stress (2.73 ± 0.82 vs. 2.63 ± 0.84 mL min(-1)g(-1), respectively, P = 0.01). At a regional level, for resting conditions small (<10%) but significant discrepancies were noted in each vascular territory while for stress MBF, a significant difference was only observed for the LAD region. Differences between SP for the LAD territory were abolished after exclusion of the distal apical segment, which is susceptible to spillover artefacts. An excellent correlation between MBF values was found for global (r = 0.96) and regional MBF (r > 0.94 for all). CONCLUSION For global and regional MBF, Carimas and Cardiac VUer showed excellent agreement and intra-observer reproducibility. These results confirm that, for patients with intermediate likelihood of CAD, these validated SP are interchangeable and can be utilized for routine clinical practice of (15)O-water cardiac PET.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Positron emission tomography in paediatric cardiology.

Types of PET study There are three types of cardiac PET study: regional blood flow (which can be measured at rest and during pharmacological induced stress), substrate metabolism, and chemical recognition (including receptors and enzymes). Currently, the main clinical application of PET is in the diagnosis of coronary artery disease, in terms of the diVerentiation between infarcted and “stunned...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

Quantification of subendocardial and subepicardial blood flow using 15O-labeled water and PET: experimental validation.

UNLABELLED The purpose of this study was to assess the feasibility and accuracy of quantifying subendocardial and subepicardial myocardial blood flow (MBF) and the relative coronary flow reserves (CFR) using (15)O-labeled water (H(2)(15)O) and 3-dimensional-only PET. METHODS Eight pigs were scanned with H(2)(15)O and (15)O-labeled carbon monoxide (C(15)O) after partially occluding the circumf...

متن کامل

Relationship between regional myocardial oxygenation and perfusion in patients with coronary artery disease: insights from cardiovascular magnetic resonance and positron emission tomography.

BACKGROUND It is recognized that the interplay between myocardial ischemia, perfusion, and oxygenation in the setting of coronary artery disease (CAD) is complex and that myocardial oxygenation and perfusion may become dissociated. Blood oxygen level-dependent (BOLD) cardiovascular magnetic resonance (CMR) has the potential to noninvasively measure myocardial oxygenation, whereas positron emiss...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal cardiovascular Imaging

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2014