Evaluation of the Repeatability and the Reproducibility of AL-Scan Measurements Obtained by Residents

نویسندگان

  • Mehmet Kola
  • Hikmet Duran
  • Adem Turk
  • Suleyman Mollamehmetoglu
  • Ahmet Kalkisim
  • Hidayet Erdol
چکیده

Purpose. To assess the repeatability and reproducibility of ocular biometry and intraocular lens (IOL) power measurements obtained by ophthalmology residents using an AL-Scan device, a novel optical biometer. Methods. Two ophthalmology residents were instructed regarding the AL-Scan device. Both performed ocular biometry and IOL power measurements using AL-Scan, three times on each of 128 eyes, independently of one another. Corneal keratometry readings, horizontal iris width, central corneal thickness, anterior chamber depth, pupil size, and axial length values measured by both residents were recorded together with IOL power values calculated on the basis of four different IOL calculation formulas (SRK/T, Holladay, and HofferQ). Repeatability and reproducibility of the measurements obtained were analyzed using the intraclass correlation coefficient (ICC). Results. Repeatability (ICC, 0.872-0.999 for resident 1 versus 0.905-0.999 for resident 2) and reproducibility (ICC, 0.916-0.999) were high for all biometric measurements. Repeatability (ICC, 0.981-0.983 for resident 1 versus 0.995-0.996 for resident 2) and reproducibility were also high for all IOL power measurements (ICC, 0.996 for all). Conclusions. The AL-Scan device exhibits good repeatability and reproducibility in all biometric measurements and IOL power calculations, independent of the operator concerned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EVALUATION OF ANATOMICAL VARIATIONS OF VESTIBULAR AQUEDUCT DIMENSIONS IN TEMPOR AL BONE CT SCAN

Various dimensions of the human vestibular aqueduct were evaluated in two groups, patient and control, and these measurements were compared. Both groups were examined clinically, followed by audiometric evaluation and temporal bone high resolution CT scan. It was found that in approximately one third of the patient group (with idiopathic SNHL), the vestibular aqueduct was 1.5 mm or larger. ...

متن کامل

Possibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs

Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...

متن کامل

Electrochemical Behavior and Determination ‎of Phenylephrine at the Multi-Walled Carbon ‎Nanotubes/ionic Liquid Nanocomposite ‎Modified Electrode in the Presence of ‎Acetaminophen

A simple and high sensitive electrochemical method was developed for determination of phenylephrine (PHE) in the presence of acetaminophen (AC) at the carbon-ceramic electrode modified by multi-walled carbon nanotubes/ionic liquid nanocomposite (MWCNTs/IL/CCE). Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) and chronoamperometry methods were used for electrochemical studie...

متن کامل

Investigation of LiF, Mg and Ti (TLD-100) Reproducibility

LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses...

متن کامل

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014