An improved electronic determination of the Boltzmann constant by Johnson noise thermometry.
نویسندگان
چکیده
Recent measurements using acoustic gas thermometry have determined the value of the Boltzmann constant, k, with a relative uncertainty less than 1 × 10-6. These results have been supported by a measurement with a relative uncertainty of 1.9 × 10-6 made with dielectric-constant gas thermometry. Together, the measurements meet the requirements of the International Committee for Weights and Measures and enable them to proceed with the redefinition of the kelvin in 2018. In further support, we provide a new determination of k using a purely electronic approach, Johnson noise thermometry, in which the thermal noise power generated by a sensing resistor immersed in a triple-point-of-water cell is compared to the noise power of a quantum-accurate pseudo-random noise waveform of nominally equal noise power. The experimental setup differs from that of the 2015 determination in several respects: a 100 Ω resistor is used as the thermal noise source, identical thin coaxial cables made of solid beryllium-copper conductors and foam dielectrics are used to connect the thermal and quantum-accurate noise sources to the correlator so as to minimize the temperature and frequency sensitivity of the impedances in the connecting leads, and no trimming capacitors or inductors are inserted into the connecting leads. The combination of reduced uncertainty due to spectral mismatches in the connecting leads and reduced statistical uncertainty due to a longer integration period of 100 d results in an improved determination of k = 1.380 649 7(37) × 10-23 J K-1 with a relative standard uncertainty of 2.7 × 10-6 and a relative offset of 0.89 × 10-6 from the CODATA 2014 recommended value. The most significant terms in the uncertainty budget, the statistical uncertainty and the spectral-mismatch uncertainty, are uncorrelated with the corresponding uncertainties in the 2015 measurements.
منابع مشابه
Electronic Measurement of the Boltzmann Constant with a Quantum-Voltage- Calibrated Johnson-Noise Thermometer
Currently, the CODATA value of the Boltzmann constant is dominated by a single gas-based thermometry measurement with a relative standard uncertainty of 1.8 ×10 [1]. This paper describes an electronic approach to measuring the Boltzmann constant that compares Johnson noise from a resistor at the water triple point with a pseudo-random noise generated using quantized ac-voltage synthesis. Measur...
متن کاملJohnson Noise and Shot Noise: The Determination of the Boltzmann Constant, Absolute Zero Temperature and the Charge of the Electron
In electronic measurements, one observes “signals,” which must be distinctly above the “noise.” Noise induced from outside sources may be reduced by shielding and proper “grounding.” Less noise means greater sensitivity with signal/noise as the figure of merit. However, there exist fundamental sources of noise which no clever circuit can avoid. The intrinsic noise is a result of the thermal jit...
متن کاملJohnson Noise and Shot Noise: The Boltzmann Constant, Absolute Zero, and the Electron Charge
Electrons in conductors at finite nonzero temperatures produce measurable voltages due to thermal noise, even if the conductor is not driven by any other external voltage. The thermal noise voltage, called Johnson noise, is posited to depend only on the frequency width of the signal, as well as the temperature and resistance of the material. From the measurement of Johnson noise voltages for re...
متن کاملPrimary electronic thermometry using the shot noise of a tunnel junction.
We present a thermometer based on the electrical noise from a tunnel junction. In this thermometer, temperature is related to the voltage across the junction by a relative noise measurement with only the use of the electron charge, Boltzmann's constant, and assumption that electrons in a metal obey Fermi-Dirac statistics. We demonstrate proof-of-concept operation of this primary thermometer ove...
متن کاملBlackbody-radiation correction to the polarizability of helium
The correction to the polarizability of helium due to blackbody radiation is calculated near room temperature. A precise theoretical determination of the blackbody radiation correction to the polarizability of helium is essential for dielectric gas thermometry and for the determination of the Boltzmann constant. We find that the correction, for not too high temperature, is roughly proportional ...