Robotic tissue tracking for beating heart mitral valve surgery

نویسندگان

  • Shelten G. Yuen
  • Nikolay V. Vasilyev
  • Pedro J. del Nido
  • Robert D. Howe
چکیده

The rapid motion of the heart presents a significant challenge to the surgeon during intracardiac beating heart procedures. We present a 3D ultrasound-guided motion compensation system that assists the surgeon by synchronizing instrument motion with the heart. The system utilizes the fact that certain intracardiac structures, like the mitral valve annulus, have trajectories that are largely constrained to translation along one axis. This allows the development of a real-time 3D ultrasound tissue tracker that we integrate with a 1 degree-of-freedom (DOF) actuated surgical instrument and predictive filter to devise a motion tracking system adapted to mitral valve annuloplasty. In vivo experiments demonstrate that the system provides highly accurate tracking (1.0 mm error) with 70% less error than manual tracking attempts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound Servoing of Catheters for Beating Heart Valve Repair

Robotic cardiac catheters have the potential to revolutionize heart surgery by extending minimally invasive techniques to complex surgical repairs inside the heart. However, catheter technologies are currently unable to track fast tissue motion, which is required to perform delicate procedures inside a beating heart. This paper presents an actuated catheter tool that compensates for the motion ...

متن کامل

Robotic Catheters for Beating Heart Surgery

Compliant and flexible cardiac catheters provide direct access to the inside of the heart via the vascular system without requiring clinicians to stop the heart or open the chest. However, the fast motion of the intracardiac structures makes it difficult to modify and repair the cardiac tissue in a controlled and safe manner. In addition, rigid robotic tools for beating heart surgery require th...

متن کامل

Robotic Force Stabilization for Beating Heart Intracardiac Surgery

The manipulation of fast moving, delicate tissues in beating heart procedures presents a considerable challenge to surgeons. We present a new robotic force stabilization system that assists surgeons by maintaining a constant contact force with the beating heart. The system incorporates a novel, miniature uniaxial force sensor that is mounted to surgical instrumentation to measure contact forces...

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

Results of beating heart mitral valve surgery via the trans-septal approach.

OBJECTIVE Mitral valve surgery can be performed through the trans-atrial or the trans-septal approach. Although the trans-atrial is the preferred method, the trans-septal approach has also been used recently and has a particular value in beating-heart mitral valve surgery. Herein we report our experience with beating-heart mitral valve surgery via trans-septal approach, and discuss its advantag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image analysis

دوره 17 8  شماره 

صفحات  -

تاریخ انتشار 2013