Terahertz imaging and spectroscopy based on hot electron bolometer (HEB) heterodyne detection*

نویسندگان

  • Eyal Gerecht
  • Lixing You
چکیده

Imaging and spec troscopy at terahertz fre quencies have great po tential for healthcare, plasma di ag nos tics, and homeland secu rity ap pli ca tions. Terahertz fre quen cies cor re spond to en ergy level tran si tions of im por tant mol e cules in bi ol ogy and as trophys ics. Terahertz ra di a tion (T-rays) can pen e trate cloth ing and, to some ex tent, can also pen e trate bi o log i cal ma te ri als. Because of their shorter wave lengths, they of fer higher spatial resolution than do microwaves or millimeter waves. We are developing hot electron bolometer (HEB) mixer receivers for heterodyne detection at terahertz frequencies. HEB detectors provide unprecedented sensitivity and spectral resolution at terahertz frequencies. We describe the development of a two-pixel focal plane array (FPA) based on HEB technology. Furthermore, we have demonstrated a fully automated, two-dimensional scanning, pas sive imaging system based on our HEB technology operating at 0.85 THz. Our high spectral resolution terahertz imager has a to tal sys tem noise equivalent temperature difference (NE T) value of better than 0.5 K and a spatial resolution of a few millimeters. HEB technology is becoming the basis for advanced terahertz imaging and spectroscopic technologies for the study of biological and chemical agents over the entire terahertz spectrum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of Superconducting Hot-Electron Bolometer Mixers for Terahertz-Band Astronomy

Recently, a next-generation heterodyne mixer detector— a hot electron bolometer (HEB) mixer employing a superconducting microbridge—has gradually opened up terahertz-band astronomy. The surrounding state-of-the-art technologies including fabrication processes, 4 K cryostats, cryogenic low-noise amplifiers, local oscillator sources, micromachining techniques, and spectrometers, as well as the HE...

متن کامل

Integration of a Mobile Terahertz Spectroscopic System based on HEB Heterodyne Detection

We are developing a mobile heterodyne terahertz system based on hot electron bolometer (HEB) mixer receivers to both image and obtain spectra from biological samples. An HEB mixer provides unprecedented sensitivity and spectral resolution at terahertz frequencies. We have recently demonstrated a lownoise heterodyne passive imager operating at 0.85 THz [1]. A heterodyned HEB detector integrated ...

متن کامل

Low Noise Receivers Based on Superconducting Niobium Nitride Hot Electron Bolometer Mixers from 0.65 to 3.1 Terahertz

Low noise terahertz (THz) receivers based on superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna’s inner terminals on a high-resistivity Si substrate. To eliminate the influence of direct det...

متن کامل

Full characterization and analysis of a terahertz heterodyne receiver based on a NbN hot electron bolometer

We present a complete experimental characterization of a quasioptical twin-slot antenna coupled small area 1.0 0.15 m2 NbN hot electron bolometer HEB mixer compatible with currently available solid state tunable local oscillator LO sources. The required LO power absorbed in the HEB is analyzed in detail and equals only 25 nW. Due to the small HEB volume and wide antenna bandwidth, an unwanted d...

متن کامل

MgB2 hot-electron bolometer mixers for THz heterodyne instruments

In this work we present experimental investigation of the MgB2 hot-electron bolometer (HEB) for low noise mixing at terahertz frequencies. A dedicated MgB2 thin film deposition system was designed and constructed based on Hybrid Physical-Chemical Deposition. Films as thin as 15nm have a superconducting transition at 35K, with a critical current density >107 A/cm2 (at 4.2K) in bridges as narrow ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008