Toward point-of-care management of chronic respiratory conditions: Electrochemical sensing of nitrite content in exhaled breath condensate using reduced graphene oxide
نویسندگان
چکیده
We present a portable non-invasive approach for measuring indicators of inflammation and oxidative stress in the respiratory tract by quantifying a biomarker in exhaled breath condensate (EBC). We discuss the fabrication and characterization of a miniaturized electrochemical sensor for detecting nitrite content in EBC using reduced graphene oxide. The nitrite content in EBC has been demonstrated to be a promising biomarker of inflammation in the respiratory tract, particularly in asthma. We utilized the unique properties of reduced graphene oxide (rGO); specifically, the material is resilient to corrosion while exhibiting rapid electron transfer with electrolytes, thus allowing for highly sensitive electrochemical detection with minimal fouling. Our rGO sensor was housed in an electrochemical cell fabricated from polydimethyl siloxane (PDMS), which was necessary to analyze small EBC sample volumes. The sensor is capable of detecting nitrite at a low over-potential of 0.7 V with respect to an Ag/AgCl reference electrode. We characterized the performance of the sensors using standard nitrite/buffer solutions, nitrite spiked into EBC, and clinical EBC samples. The sensor demonstrated a sensitivity of 0.21 μA μM 1 cm 2 in the range of 20–100 μM and of 0.1 μA μM 1 cm 2 in the range of 100–1000 μM nitrite concentration and exhibited a low detection limit of 830 nM in the EBC matrix. To benchmark our platform, we tested our sensors using seven pre-characterized clinical EBC samples with concentrations ranging between 0.14 and 6.5 μM. This enzyme-free and label-free method of detecting biomarkers in EBC can pave the way for the development of portable breath analyzers for diagnosing and managing changes in respiratory inflammation and disease.
منابع مشابه
Measurement of Exhaled Nitric Oxide and Exhaled Breath Condensate in the Diagnosis and Management of Asthma and Other Respiratory Disorders
Description of Procedure or Service Current techniques for diagnosing and monitoring asthma and predicting exacerbations are suboptimal. Two new strategies, evaluation of exhaled nitric oxide and exhaled breath condensate are proposed. These techniques are also potentially useful in the management of other conditions such as chronic obstructive pulmonary disease (COPD) and chronic cough. There ...
متن کاملElectrochemical Chiral Recognition of Naproxen Using L-Cysteine/Reduced Graphene Oxide Modified Glassy Carbon Electrode
The electrochemical response of S- and R-naproxen enantiomers was investigated on L-cysteine/reduced graphene oxide modified glassy carbon electrode (L-Cys/RGO/GCE). The production of the reduced graphene oxide and L-cysteine on the surface of the glassy carbon electrode was done by using electrochemical processes. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were us...
متن کاملWill use of exhaled breath condensate be useful for the intensive care unit routine?
Endogenous production of nitric oxide can be detected and monitored in exhaled air of men and animals. The main objective of this review was to discuss if nitric oxide in exhaled breath condensate is a useful tool when investigating respiratory dysfunctions in intensive care units. Specialized literature reveals an increasing interest in the use of exhaled breath condensate as a non-invasive me...
متن کاملIndependent information of nonspecific biomarkers in exhaled breath condensate.
BACKGROUND Exhaled breath condensate (EBC) has been used for diagnosing and monitoring respiratory disorders. For clinical purposes the assessment of easy-to-obtain nonspecific markers seems particularly interesting. OBJECTIVES As these measures are related to each other, our objective was to extract the independent information in global EBC markers across a range of respiratory disorders. ...
متن کاملRESPIRATORY PHYSIOLOGY Effects of breathing pattern and inspired air conditions on breath condensate volume, pH, nitrite, and protein concentrations
Background: The effects of breathing pattern and inspired air conditions on the volume and content of exhaled breath condensate (EBC) were investigated. Methods: Total exhaled water (TEW), EBC volume, pH, nitrite and protein concentrations were measured in three groups of 10 healthy subjects breathing into a condenser at different target minute ventilations (Vm), tidal volumes (Vt), and inspire...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017