Cervical spondylosis: three-dimensional gradient-echo MR with magnetization transfer.
نویسندگان
چکیده
PURPOSE To compare a three-dimensional Fourier transform (3DFT) gradient-echo pulse sequence with magnetization transfer at a short echo time against standard 3DFT gradient-echo technique in the evaluation of cervical spondylosis, specifically addressing the effects of motion and susceptibility artifacts on the dimensions of the neural foramina and contrast at the cerebrospinal fluid (CSF)-spinal cord interface. METHODS Ten patients with clinically suspected cervical spondylosis were examined with axial MR imaging using both our standard 3DFT gradient-echo sequence and a 3DFT gradient-echo sequence with a short echo time plus magnetization transfer. Two neuroradiologists measured the transverse dimensions of 22 diseased neural foramina and graded the contrast at the CSF-spinal cord interface. RESULTS Sixteen of 22 affected neural foramina were larger in the transverse dimension when the magnetization transfer technique was used than when the standard 3DFT gradient-echo sequence was used. In 9 of 10 patients superior contrast was seen at the CSF-spinal cord interface on images obtained with the magnetization transfer technique. CONCLUSIONS In the cervical spine, 3DFT gradient-echo imaging with magnetization transfer improves contrast and sharpness of the CSF-spinal cord interface at short echo times. This results in less exaggeration of the neural foraminal stenosis as compared with that seen with standard 3DFT gradient-echo techniques owing to the diminished effects of motion and susceptibility artifacts.
منابع مشابه
Magnetic susceptibility artifacts in gradient-recalled echo MR imaging.
Artifacts related to magnetic susceptibility differences between bone and soft tissue are prevalent on gradient-recalled echo images, particularly when long echo delay times are used. These susceptibility artifacts spatially distort and artifactually enlarge bone contours. This can alter the apparent shape of the spinal canal and exaggerate the degree of spinal stenosis seen in patients with ce...
متن کاملT1-weighted three-dimensional magnetization transfer MR of the brain: improved lesion contrast enhancement.
PURPOSE We developed and evaluated clinically T1-weighted three-dimensional gradient-echo magnetization transfer (MT) sequences for contrast-enhanced MR imaging of the brain. METHODS A short-repetition-time, radio frequency-spoiled, 3-D sequence was developed with a 10-millisecond MT pulse at high MT power and narrow MT pulse-frequency offset, and the enhancing lesion-to-normal white matter b...
متن کاملCervical spine: three-dimensional fast spin-echo MR imaging--improved recovery of longitudinal magnetization with driven equilibrium pulse.
Author contributions: Guarantor of integrity of entire study, E.R.M.; study concepts and design, E.R.M.; definition of intellectual content, E.R.M.; literature research, E.R.M.; clinical studies, E.R.M.; data acquisition, E.R.M., R.I.; data analysis, E.R.M., R.I.; manuscript preparation, E.R.M., R.I.; manuscript editing, E.R.M., R.I., P.J.M.F.; manuscript review, E.R.M., R.I., P.J.M.F. Cervical...
متن کاملMagnetization transfer (MT) asymmetry around the water resonance in human cervical spinal cord.
PURPOSE To demonstrate the presence of magnetization transfer (MT) asymmetry in human cervical spinal cord due to the interaction between bulk water and semisolid macromolecules (conventional MT), and the chemical exchange dependent saturation transfer (CEST) effect. MATERIALS AND METHODS MT asymmetry in the cervical spinal cord (C3/C4-C5) was investigated in 14 healthy male subjects with a 3...
متن کاملProton MR spectroscopy and magnetization transfer ratio in multiple sclerosis: correlative findings of active versus irreversible plaque disease.
PURPOSE To characterize plaques of multiple sclerosis (MS) using both proton MR spectroscopy and magnetization transfer (MT) imaging. METHODS The magnetization transfer ratio (MTR) was calculated from two series of three-dimensional gradient-recalled acquisition in the steady state (GRASS) images obtained with and without an MT saturation pulse. Proton spectra were acquired using the point-re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 17 4 شماره
صفحات -
تاریخ انتشار 1996