3d Model Measuring System
نویسندگان
چکیده
With the rapid development of digital technology, we can now obtain easily the image with high resolution capability or the detailed 3D (Three-dimensional) data of the object by the technique of laser scanner or digital photogrammetry. And as we can now make a 3D model with real texture from these data by using the CG (Computer Graphics) technology, new business chance is expanding in the domain of CG and GIS as regard to city planning, architecture, maintenance, cultural assets. However, to do all this, a lot of time and work is required as we have to deal with enormous amount of data. To solve this problem, therefore, we have now developed and added a new function to our PC-based Digital Photogrammetry System which can produce a 3D model from digital camera’s image. This new function can handle all the photo-image data obtained from high altitude (above 1000m) and low altitude (above 100m) aerial as well as the ground photography and can produce a 3D model incorporating simultaneously all these data altogether. Furthermore, in order to simplify the operation, we have succeeded to develop a new photoguiding system to guide the photo-shooting and make simulation on the display in which the object is shown in real time. Here we superimpose on the display the data of plan, the data of the position of the control points on the object as seen from the shooting position of camera or the data of 3D obtained from aerial photograph so that the computer can guide and simulate the shooting position for the best possible result. In this way, even if we change the shooting position, we can always show the CG of such thing as control points at the most desired place on the display. In the following presentation, therefore, we are going to demonstrate how we have confirmed the validity of our system by making 3D measurement and 3D model out of the digital pictures taken by high altitude airplane, low altitude aircraft (e.g. powered paraglider) and the pictures taken on the ground.
منابع مشابه
Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملCamera Arrangement in Visual 3D Systems using Iso-disparity Model to Enhance Depth Estimation Accuracy
In this paper we address the problem of automatic arrangement of cameras in a 3D system to enhance the performance of depth acquisition procedure. Lacking ground truth or a priori information, a measure of uncertainty is required to assess the quality of reconstruction. The mathematical model of iso-disparity surfaces provides an efficient way to estimate the depth estimation uncertainty which ...
متن کاملCorrection: Measuring the effects of fractionated radiation therapy in a 3D prostate cancer model system using SERS nanosensors.
Correction for 'Measuring the effects of fractionated radiation therapy in a 3D prostate cancer model system using SERS nanosensors' by Victoria L. Camus, et al., Analyst, 2016, 141, 5056-5061.
متن کاملDesigning the Virtual Model of a Mechatronic Micro- Positioning and Micro-measuring System for Experimental Model Realization
This paper aims is to present the realization of a virtual model, as well as the experimental model for a mechatronic micro-positioning and micro-measuring system on two axes, OX, and OZ respectively. The paper also includes experimental results on measuring the gripping force developed between the fingers of an electrical micro-gripper, with two fingers, incorporated into the experimental mode...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملMeasuring the effectiveness of human resource information systems in national iranian oil company an empirical assessment
While the growth of MIS investment and its influence is making MIS evaluation ever more indispensable, little attention has been paid to assessing and communicating system effectiveness. This paper attempts to empirically assess the effectiveness of integrated human resource information system in Iranian oil industry. As suggested by recent research, the widely accepted IS success model is...
متن کامل