Comparing the complications of 2 copper intrauterine devices: T380A and Cu-Safe 300.
نویسندگان
چکیده
This single-blind case-control study compared the complications of 2 intrauterine devices in consecutive referrals for device insertion in clinics of Shaheed Beheshti University of Medical Sciences, Islamic Republic of Iran. Women who met the inclusion criteria (n = 110) were randomly allocated to receive copper T380A (controls) or Cu-Safe 300 (cases). Moderate or severe pain during the device insertion was reported in 69.1% of controls and 47.3% of cases. Bleeding, vertigo and crampy pain at insertion were not significantly different between the groups. After 3 months follow-up, blood spotting was reported in 16.3% and 32.7% of controls and cases respectively. The Cu-Safe-300 group had less pain and menstrual bleeding but copper T380A had less spotting after 3 months. Studies on longer term complications are strongly recommended.
منابع مشابه
Comparison of failure rates of CU t 380 A and CU safe 300 IUDs four years after insertion
Changavi F1, janani F1, Asti P1, Akbari S2 1. Instructor, Department of midwifery, Faculty of nursing and midwifery, Lorestan University of Medical Sciences 2. Instructor, Department of gynecology, Faculty of medicine, Lorestan University of Medical Sciences Abstract Background: IUD is a useful and effective tool for family planning. Different kinds of this equipment are available at ...
متن کاملContraceptive failure with Copper T380A intrauterine device (IUD): A single tertiary center experience
OBJECTIVE The objective of this study was to assess the risk factors of pregnancy with Copper (Cu)T380A IUD and pregnancy outcomes. METHODS A retrospective study evaluating the risk factors and pregnancy outcomes of 81 patients who conceived with CuT380A IUD in situ. RESULTS Four ectopic pregnancies and 77 intrauterine pregnancies were detected. Twenty-six pregnancies (33.76%, 26/77) were t...
متن کاملImmediate postpartum insertion of an intrauterine contraceptive device.
An intrauterine contraceptive device (iucd) is a widely acceptable reversible method of contraception for spacing of births. We determined the efficacy and safety of immediate postpartum iucd insertion during cesarean section. One hundred twenty two women with term pregnancies delivering by cesarean section between January 2012 to June 2013 were included in the study. A copper iucd (cu T380A) w...
متن کاملTolerability of The Copper- T Intrauterine Device by Acceptors at Jos University Teaching Hospital, Jos, North-Central Nigeria
Background: The Copper-T (Cu-T) Intrauterine device (IUD) is one of the oldest and most reliable forms of contraception. Its widespread use has been limited by side effects, such as heavy menstrual flow and pain on insertion. Findings suggest that the intrauterine device acts more as a contraceptive than an abortifacient, thus improving its acceptability. Objectives: To determine the proportion...
متن کاملEffective inhibition of the early copper ion burst release with ultra-fine grained copper and single crystal copper for intrauterine device application.
To solve the main problems of existing coarse grained copper (CG Cu) intrauterine devices (IUD)-namely burst release and a low transfer efficiency of the cupric ions during usage-ultra-fine grained copper (UFG Cu) and single crystal copper (SC Cu) have been investigated as potential substitutes. Their corrosion properties with CG Cu as a control have been studied in simulated uterine fluid (SUF...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Eastern Mediterranean health journal = La revue de sante de la Mediterranee orientale = al-Majallah al-sihhiyah li-sharq al-mutawassit
دوره 14 1 شماره
صفحات -
تاریخ انتشار 2008