A Tracer Analysis Study on the Redistribution and Oxidization of Endogenous Carbon Monoxide in the Human Body
نویسندگان
چکیده
Past studies have suggested that some carbon monoxide (CO) moves from blood haemoglobin to tissue cells and that mitochondrial cytochrome c oxidase oxidizes CO to carbon dioxide (CO(2)). However, no study has demonstrated this redistribution and oxidization of CO under physiological conditions. The objective of this study was to trace the redistribution and oxidization of CO in the human body by detecting (13)CO(2) production after the inhalation of (13)CO. In Experiment 1, we asked a healthy subject to inhale 50 ppm (13)CO gas. In Experiment 2, we circulated heparinized human blood in a cardio-pulmonary bypass circuit and supplied 50 ppm (13)CO gas to the oxygenator. We sequentially sampled exhaled and output gases and measured the (13)CO(2)/(12)CO(2) ratios. In Experiment 1, the exhaled (13)CO(2)/(12)CO(2) ratio increased significantly between 4 to 31 h of (13)CO inhalation. In Experiment 2, the output (13)CO(2)/(12)CO(2) ratio showed no significant increase within 36 h of (13)CO input. Experiment 1 demonstrated the oxidization of CO in the human body under physiological conditions. Experiment 2 confirmed that oxidization does not occur in the circulating blood and indicated the redistribution of CO from blood carboxyhaemoglobin to tissue cells.
منابع مشابه
Demonstration and quantification of the redistribution and oxidation of carbon monoxide in the human body by tracer analysis
Numerous studies have confirmed the role of endogenous carbon monoxide (CO) gas as a signal transmitter. However, CO is considered an intracellular transmitter, as no studies have demonstrated the redistribution of CO from the blood to tissue cells. Tracer analyses of 13CO2 production following 13CO gas inhalation demonstrated that CO is oxidized to carbon dioxide (CO2) in the body and that CO ...
متن کاملAnalysis of temporal - spatial distribution Carbon monoxide gas in the atmosphere of Iran using Aqua/AIRS data
Considering the vital importance of air and the increasing trace of its contaminating factors, it is necessary to study the contaminating factors in order to be aware of the existing situation. The phenomenon of air pollution is one of the most important problems in many parts of Iran, due to several reasons, increasing the amount of it day by day. Carbon monoxide is one of the most dangerous p...
متن کاملPnm-19: Residential Exposure to Carbon Monoxide and Spontaneous Abortion
Background: The relationship between air pollution exposure and adverse birth outcomes such as low birth weight and IUGR was studied. However, very few studies evaluated the effect of air pollution emissions on spontaneous abortion. We examined association between spontaneous abortion of the first trimester of pregnancy and ambient concentrations of carbon monoxide in Tehran. Materials and Meth...
متن کاملAn Epidemiological Study of Carbon Monoxide Poisoning Rate and a Comparison with Other Poisonings Recorded in Mazandaran Department of Forensic Medicine, 2009-2011
Background: Carbon monoxide is an odorless, colorless and poisonous gas. Since there is currently no information on the prevalence of carbon monoxide poisoning in Mazandaran, this study aimed to investigate the prevalence of carbon monoxide poisoning and compare its prevalence with other poisonings recorded in Mazandaran Department of Forensic Medicine, from 2009 to 2011.Methods: This is a de...
متن کاملAdsorption of Carbon Monoxide on a (6, 6) Armchair Carbon Nanotube: Ab initio Study
Perhaps the more interesting nanostructures with large application potential, from transistors to probes, are carbon nanotubes. One of the most widely uses of these nanostructures are their applications as gas detector, which is an important application in the field se of environmental technologies. The present work studies the adsorption of carbon monoxide on a (6, 6) armchair carbon nanotube ...
متن کامل