Proton radiotherapy dose perturbations caused by esophageal stents of varying material composition are negligible in an experimental model
نویسندگان
چکیده
BACKGROUND Self-expanding metal and plastic esophageal stents (SEMS and SEPS, respectively) are used in conjunction with chemoradiation for palliation of malignant dysphagia. To date, the dosimetric effects of stents undergoing proton radiotherapy are not known. STUDY AIM To investigate the proton radiotherapy dose perturbations caused by esophageal stents of varying designs and materials undergoing external beam treatment for esophageal cancer. PATIENTS AND METHODS Simulated clinical protocol. Solid acrylic phantom was used to mimic the esophageal tissue environment. Stents made of nitinol, stainless steel and polyester were tested. Proton beam dose of 2 Gy-E was delivered to each stent in a single anterior to posterior field. Film and image based evidence of dose perturbation were main outcomes measured. RESULTS Only the stainless steel and plastic stents demonstrated slight overall dose attenuations (- 0.5 % and - 0.4 %, respectively). All the nitinol-based stents demonstrated minimal overall dose perturbations ranging from 0.0 % to 1.2 %. Negligible dose perturbations were observed on each of the stent surfaces proximal to the radiation source, ranging from - 0.8 % (stainless steel stent) to 1.0 % (nitinol stent). Negligible dose effects were also observed on the distal surfaces of each stent ranging from - 0.5 % (plastic and stainless steel stents) to 1.0 % (nitinol stent). CONCLUSION Proton radiotherapy dose perturbations caused by stents of varying designs and material composition are negligible. Negligible dose perturbation is in keeping with the inherent advantage of proton therapy over traditional radiotherapy composed of photons - given its relative large mass, protons have little side scatter.
منابع مشابه
Dosimetric comparison between four kinds of radioactive esophageal stents to be used in the treatment of advanced esophageal cancers using Monte Carlo simulation
Finding accurate methods to be employed for the treatment of esophageal cancers is of especial interest for researchers, due to the sensitivity of this tissue. Recently radioactive stents loaded with I-125 brachytherapy seeds have been widely investigated for the treatment of advanced esophageal cancer. It is necessary to investigate the dose distribution of any radioactive esophageal stents be...
متن کاملProton dose perturbations caused by high‐voltage leads from implanted cardioverter defibrillators
An increasing number of patients undergoing proton radiotherapy have cardiac implantable electrical devices (CIEDs). We recently encountered a situation in which a high-voltage coil on a lead from an implanted cardiac defibrillator was located within the clinical treatment volume for a patient receiving proton radiotherapy for esophageal cancer. To study the effects of the lead on the dose deli...
متن کاملAssessment of secondary particles in breast proton therapy by Monte Carlo simulation code using MCNPX
Background: The present study aimed to investigate the equivalent dose in vital organs, including heart and lung, due to secondary particles produced during breast proton therapy. Materials and Methods: The numerical ORNL female-phantom was improved and simulated using the Monte Carlo MCNPX code. The depth-dose profile of proton beams with different energies was simulated. The proper energy ran...
متن کاملCalculation of Neutron Dose Ratio of Heart, Lung and Liver due to breast cancer Proton Therapy using MCNPX code
Introduction: The proton beam produced in particle accelerators has an appropriate therapeutic potential. In this research, proton therapy of breast cancer is simulated using the MCNPX code in a MIRD phantom, also the contribution of scattered neutron dose during the proton therapy were calculated for the Heart, Lung and Liver. Materials and Methods: For si...
متن کاملDevelopment of an Accommodation-Dependent Eye Model and Studying the Effects of Accommodation on Electron and Proton Dose Conversion Coefficients
Introduction International Commission on Radiological Protection (ICRP) has provided a comprehensive discussion on threshold dose for radiation-induced cataract in ICRP publication 116. Accordingly, various parts of the eye lens have different radio-sensitivities. Recently, some studies have been performed to develop a realistic eye model with the aim of providing accurate estimation of fluence...
متن کامل