Application of electrospray mass spectrometry in probing protein-protein and protein-ligand noncovalent interactions.

نویسندگان

  • E C Huang
  • B N Pramanik
  • A Tsarbopoulos
  • P Reichert
  • A K Ganguly
  • P P Trotta
  • T L Nagabhushan
  • T R Covey
چکیده

A novel mass spectrometry-based methodology using electrospray ionization (ESI) is described for the detection of protein-protein [interferon (IFN)-γ dimer] and protein-ligand [ras-guanosine diphosphate (GDP)] noncovalent interactions. The method utilizes ESI from aqueous solution at appropriate pH. The presence of the noncovalent complex of the IFN-γ dimer was confirmed by the observed average molecular weight of 33,819 Da. The key to the detection of the IFN-γ dimer is the use of an alkaline solution (pH ≈ 9) for sample preparation and for mass spectrornetry analysis. The effect of the declustering energy in the region of the ion sampling orifice and focusing quadrupole on the preservation of the gas-phase noncovalent complex (IFN-γ dimer) was also studied. The effect of the declustering energy on complex dissociation was further extended to probe the noncovalent protein-ligand association of ras-GDP. It was found that little energy is required to dissociate the IFN-γ dimer, whereas a substantial amount of energy is required to dissociate the gas-phase ras-GDP complex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Studying noncovalent protein complexes by electrospray ionization mass spectrometry.

Electrospray ionization mass spectrometry has been used to study protein interactions driven by noncovalent forces. The gentleness of the electrospray ionization process allows intact protein complexes to be directly detected by mass spectrometry. Evidence from the growing body of literature suggests that the ESI-MS observations for these weakly bound systems reflect, to some extent, the nature...

متن کامل

Mass spectrometry of protein-ligand complexes: enhanced gas-phase stability of ribonuclease-nucleotide complexes.

Noncovalent protein-ligand complexes are readily detected by electrospray ionization mass spectrometry (ESI-MS). Ligand binding stoichiometry can be determined easily by the ESI-MS method. The ability to detect noncovalent protein-ligand complexes depends, however, on the stability of the complexes in the gas-phase environment. Solution binding affinities may or may not be accurate predictors o...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 4 8  شماره 

صفحات  -

تاریخ انتشار 1993