A Comparative Study of Average, Linked Mastoid, and REST References for ERP Components Acquired during fMRI
نویسندگان
چکیده
In simultaneous electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) studies, average reference (AR), and digitally linked mastoid (LM) are popular re-referencing techniques in event-related potential (ERP) analyses. However, they may introduce their own physiological signals and alter the EEG/ERP outcome. A reference electrode standardization technique (REST) that calculated a reference point at infinity was proposed to solve this problem. To confirm the advantage of REST in ERP analyses of synchronous EEG-fMRI studies, we compared the reference effect of AR, LM, and REST on task-related ERP results of a working memory task during an fMRI scan. As we hypothesized, we found that the adopted reference did not change the topography map of ERP components (N1 and P300 in the present study), but it did alter the task-related effect on ERP components. LM decreased or eliminated the visual working memory (VWM) load effect on P300, and the AR distorted the distribution of VWM location-related effect at left posterior electrodes as shown in the statistical parametric scalp mapping (SPSM) of N1. ERP cortical source estimates, which are independent of the EEG reference choice, were used as the golden standard to infer the relative utility of different references on the ERP task-related effect. By comparison, REST reference provided a more integrated and reasonable result. These results were further confirmed by the results of fMRI activations and a corresponding EEG-only study. Thus, we recommend the REST, especially with a realistic head model, as the optimal reference method for ERP data analysis in simultaneous EEG-fMRI studies.
منابع مشابه
Electrophysiological Correlates of Change Detection during Delayed Matching Task: A Comparison of Different References
Detecting the changed information between memory representation and incoming sensory inputs is a fundamental cognitive ability. By offering the promise of excellent temporal resolution, event-related potential (ERP) technique has served as a primary tool for studying this process with reference of the linked mastoid (LM). However, given that LM may distort the ERP signals, it is still undetermi...
متن کاملA Comparative Study on the Dynamic EEG Center of Mass with Different References
One of the most fundamental issues during an EEG study is choosing an available neutral reference. The infinity zero reference obtained by the reference electrode standardization technique (REST) has been recommended and used for its higher accuracy. This paper examined three traditional references, the average reference (AR), the linked mastoids reference (LM), and REST, in the study of the EE...
متن کاملHow Different EEG References Influence Sensor Level Functional Connectivity Graphs
Highlights: Hamming Distance is applied to distinguish the difference of functional connectivity networkThe orientations of sources are testified to influence the scalp Functional Connectivity Graph (FCG) from different references significantlyREST, the reference electrode standardization technique, is proved to have an overall stable and excellent performance in variable situations. The choice...
متن کاملA comparative study of different references for EEG default mode network: the use of the infinity reference.
OBJECTIVE The choice of electroencephalograph (EEG) reference is a critical issue for the study of brain activity. The present study addressed the use of the infinity reference obtained by the reference electrode standardisation technique (REST) in the study of EEG default mode network (DMN). METHODS A total of 100 randomly positioned source configurations, each consisting of two dipoles with...
متن کاملElectrophysiological Responses to Expectancy Violations in Semantic and Gambling Tasks: A Comparison of Different EEG Reference Approaches
Dynamically evaluating the outcomes of our actions and thoughts is a fundamental cognitive ability. Given its excellent temporal resolution, the event-related potential (ERP) technology has been used to address this issue. The feedback-related negativity (FRN) component of ERPs has been studied intensively with the averaged linked mastoid reference method (LM). However, it is unknown whether FR...
متن کامل