True power factor metering for m-wire systems with distortion, unbalance and direct current components
نویسندگان
چکیده
Two companion papers describe an internally consistent general power theory valid for instantaneous and average power for systems with any number of wires, under conditions of unbalance, distortion or dc components. Measuring apparent power and power factor under non-ideal conditions, even in typical three-phase four wire systems, needs the resistances of the wires, particularly the neutral wire, to be defined, and without this detail all conventional power theory approaches are inadequate and give misleading measurement results. This paper illustrates the practicality of measurement of distorted power supplies, and describes laboratory tests showing the differences between measurements using the new approach and a conventional instrument. Applications of the new approach in real power systems are described, including hybrid ac/dc systems and smart grids, and in measuring quality of supply affected by disturbing loads, and the non-active power in transformers subjected to geomagnetically induced currents. The nature of changes required in international standards and the implications for further practical research and development are identified. © 2012 Elsevier B.V. All rights reserved.
منابع مشابه
The New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace
The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...
متن کاملThe New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace
The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...
متن کاملInvestigation of Power Factor Behavior in AC Railway System Based on Special Traction Transformers
The single-phase traction load has essentially an unbalance characteristic at the Point of Common Coupling (PCC), which injects harmonic into the utility grid. In this paper, the effect of harmonic distortion and unbalance loading are investigated simultaneously for electrical railway systems. Special traction transformers (i.e. single-phase, V/V, Wye-Delta, Scott, and Le Blanc) are used betwee...
متن کاملComparative Power Quality Analysis of Different DSTATCOM Topologies
This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...
متن کاملControl Of Grid-Interfacing Inverter For Wind Energy Integration With Power Quality Management At Distribution Level
There is growing interest in renewable energy around the world. Since most renewable sources are intermittent in nature, it is a challenging task to integrate renewable energy resources into the power grid infrastructure. Distribution systems provide standby service during utility outages and when operated during peak load hours, potentially reduce energy costs. This paper presents a grid inter...
متن کامل