Torsional resistance and wear of a modular sleeve-stem hip system.

نویسندگان

  • S D Cook
  • M T Manley
  • M A Kester
  • N G Dong
چکیده

The torsional resistance and wear debris generation of the modular sleeve and stem S-ROM total hip system was evaluated. The results indicate that slippage of the sleeve-stem interface may occur under physiological loading conditions. Slippage is more likely to occur if the junction is contaminated by blood or tissue, or if the stem is disengaged and reimplanted into the sleeve. Significant wear debris was generated during cyclic fatigue loading. The wear debris was of the size (less than 10 mum) readily ingested by macrophages. Particles of these dimensions have been associated with osteolysis, implant loosening and pain. Based upon the findings of this study the implantation of this type system must be carefully considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-Term Results of Cementless Total Hip Arthroplasty Using a Modular Stem in Patients with Femoral Head Osteonecrosis

Cementless modular stemwas designed to allow the surgeon to independently match the anatomy of the metaphyseal and diaphyseal regions of the femoral canal of an individual patient.1 S-ROM stem (DePuy/Johnson & Johnson), which has a hollow proximal sleeve and separate cylindrical core, was introduced in 1984. So far, long-term results of this prosthesis have been excellent in osteoarthritis, dev...

متن کامل

Modular hip implant fracture at the stem-sleeve interface.

The use of modular implants in femoral stem design has grown increasingly popular over the last decade because of the theoretical advantage of more flexibility and optimization of femoral anteversion, limb length, and femoral component offset. With the benefit of increased surgical flexibility, however, modularity also carries the theoretical risks of fretting at the modular surfaces, sequelae ...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

Designing a High Resistant, High-torque Downhole Drilling Motor (RESEARCH NOTE)

Downhole drilling motors or mud motors are frequently used during the oil and gas well construction, especially for construction of directional and horizontal segments. However, low operation life of the down hole drilling motors and high rate of wear in their working elements may constrain their application due to technical and economical disadvantageousness. In this work, a high-torque modula...

متن کامل

Total hip arthroplasty using proximal porous coating stem with distal sleeve: mid-term outcome.

PURPOSE To report mid-term results of total hip arthroplasty (THA) using the Opti-Fix Plus Hip System (Opti-Fix Hip), and to assess the correlations between peri-implant bone changes and the distal medullary occupancy rate. METHODS 11 men (13 hips) and 53 women (58 hips) aged 24 to 87 (mean, 61) years underwent THA using the Opti-Fix Hip, with a modular stem and a distal sleeve, and were foll...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical materials

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 1993