Refining the measurement of rate constants in the BIAcore.
نویسنده
چکیده
When estimating rate constants using the BIAcore surface plasmon resonance (SPR) biosensor, one must have an accurate mathematical model to interpret sensogram data. Several models of differing complexity are discussed, including the effective rate constant (ERC) approach. This model can be shown formally to be good within O(Da) in the limit of small Damköhler number Da, which is the ratio of the reaction rate to the rate of transport to the surface. Numerical results are presented that show that except for very slow reactions, parameter estimates from the ERC model are very close to those estimated using a more complicated model. The BIAcore measures the behavior of an evanescent wave whose signal strength decays as it penetrates into the device. It is shown that this decay does not appreciably affect the sensogram readout at low Da, but at moderate Da can lead to situations where two vastly different rate constants can produce the same short-time sensogram data.
منابع مشابه
The effect of a receptor layer on the measurement of rate constants.
Many cellular reactions involve a reactant in solution binding to or dissociating from a reactant attached to a surface. Most studies assume that the reactions occur on this surface, when in actuality the receptors usually lie in a thin layer on top of it. The effect of this layer is considered, particularly as it relates to the BIAcore measurement device, though the results are applicable to b...
متن کاملExtending the range of rate constants available from BIACORE: interpreting mass transport-influenced binding data.
Surface-based binding assays are often influenced by the transport of analyte to the sensor surface. Using simulated data sets, we test a simple two-compartment model to see if its description of transport and binding is sufficient to accurately analyze BIACORE data. First we present a computer model that can generate realistic BIACORE data. This model calculates the laminar flow of analyte wit...
متن کاملCompetition BIAcore for measuring true affinities: large differences from values determined from binding kinetics.
In attempting to use the BIAcore instrument for the determination of binding constants of several haptens or peptides to different antibodies by measuring on- and off-rates, we found that neither the absolute nor the relative values of the binding constants corresponded to the measurements in solution. Even at the lowest coupling densities useful for measurements, rebinding and bivalency effect...
متن کاملTransport effects on surface-volume biological reactions.
Many cellular reactions involve a reactant in solution binding to or dissociating from a reactant confined to a surface. This is true as well for a BIAcore, an optical biosensor that is widely used to study the interaction of biomolecules. In the flow cell of this instrument, one of the reactants is immobilized on a flat sensor surface while the other reactant flows past the surface. Both diffu...
متن کاملThe effect of receptor site nonuniformity on the measurement of rate constants
The BIAcore is an instrument for measuring rate constants in real time by using a surface–volume geometry. Though current models for the resulting reaction include transport effects for the reactant in solution, they do not account for spatial nonuniformities in the reactant attached to the wall. This work accounts for such nonuniformities and establishes that in the limit of small Damköhler nu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of mathematical biology
دوره 49 3 شماره
صفحات -
تاریخ انتشار 2004