Simultaneous Determination of Thiocyanate and Oxalate in Urine using a Carbon Ionic Liquid Electrode Modified with TiO2-Fe Nanoparticles
نویسنده
چکیده
A carbon ionic liquid electrode (CILE) modified with TiO2-Fe nanoparticles was constructed by incorporating TiO2-Fe nanoparticles into the paste matrix. Under the optimized experimental conditions, using differential pulse voltammetry (DPV), the oxidation of thiocyanate and oxalate were occurred at potentials of 0.740 V and 1.010 V, respectively, at the surface of the modified electrode. Observing a high peak current along with a suitable peak separation allowed introducing the first voltammetric sensor for simultaneous determination of these anions with high sensitivity without mutual interference. A wide linear range of 1.0 × 10-1.8 × 10 M for thiocyanate with a detection limit of 6.4 × 10 M and a wide linear range of 5.0 × 10-3.0 × 10 M for oxalate with a detection limit of 2.3 × 10 M were obtained. The modified CILE showed good reproducibility, repeatability and storage stability as well as good selectivity. The proposed sensor was successfully applied for analysis of thiocyanate and oxalate in urine samples.
منابع مشابه
Simultaneous Determination of Thiocyanate and Oxalate in Urine using a Carbon Ionic Liquid Electrode Modified with TiO2-Fe Nanoparticles
A carbon ionic liquid electrode (CILE) modified with TiO2-Fe nanoparticles was constructed by incorporating TiO2-Fe nanoparticles into the paste matrix. Under the optimized experimental conditions, using differential pulse voltammetry (DPV), the oxidation of thiocyanate and oxalate were occurred at potentials of 0.740 V and 1.010 V, respectively, at the surface of the modi...
متن کاملA Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay
We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...
متن کاملSensitive Voltammetric Detection of Indomethacin Using TiO2 Nanoparticle Modified Carbon Ionic Liquid Electrode
In this work, a TiO2 nanoparticle modified carbon ionic liquid electrode (CILE) was employed as a sensitive sensor for the investigation of the electrochemical behavior of indomethacin (IND). This nanocomposite sensor has been fabricated by incorporation of TiO2 nanoparticles and the ionic liquid 1-hexylpyridinium hexafluorophosphate (HPFP). The surface of the electrode was studied by scanning ...
متن کاملVoltammetric Determination of Tryptophan Using a Carbon Paste Electrode Modified with Magnesium Core Shell Nanocomposite and Ionic Liquids
A novel carbon paste electrode modified with ionic liquid (n-hexyl-3-methylimidazolium hexafluoro phosphate) and magnetic core-shell manganese ferrite nanoparticles (MCSILCPE) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for electro-oxidation of tryptophan, is described. Cyclic voltammetry (CV), choronoamperometry (CHA) and square wave voltammet...
متن کاملSynergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen
Monitoring the acetaminophen in biological samples and also in pharmaceutical formulations is important due to the concerns of public health care and drug safety. In this work a carbon paste electrode modified with BaTiO3 nanoparticle (BTO NPs) and room-temperature ionic liquid (IL) (n-hexyl-3-methylimidazolium hexafluoro phosphate) was fabricated. The direct electro-oxidation behavior of aceta...
متن کامل