Minimally invasive plate osteosynthesis for distal radius fractures

نویسندگان

  • Xu-ming Wei
  • Zhen-zhong Sun
  • Yong-jun Rui
  • Xiao-Jun Song
چکیده

BACKGROUND Fractures of distal radius are common injury in all age groups. Cast treatment with or without close reduction is a viable option. However, the results are often unsatisfactory with restricted function. The open reduction and internal fixation often results in extensive soft tissue dissection and associated high rates of infect and delayed/nonunion. The distractor/external fixator have reported good functional and anatomical results but the incidence of pin traction infection nerve injury and cosmedic deformity are high. We introduced a modified operative technique for minimally invasive plate osteosynthesis (MIPO) for distal radial fracture and evaluated the functional outcomes and complications. MATERIALS AND METHODS 22 distal radial fractures (10 left, 12 right) were treated using the MIPO technique and two small incisions with a palmar locking plate from August 2009 to August 2010. The wrist function was assessed according to Dienst wrist rating system, and postoperative complications were recorded. RESULTS According to Dienst wrist rating system, 13 patients showed excellent results, 6 cases showed good results and 3 patients had moderate results. No patient had poor results. Thus, the excellent and good rate was 86.4%. One patient had anesthesia in the thenar eminence and this symptom disappeared after 3 months. One patient had delayed healing in the proximal wrist crease. Two patients had mild pain on the ulnar side of the wrist and two patients had limited wrist joint function. CONCLUSION The MIPO technique by using two small palmar incisions is safe and effective for treatment of distal radial fractures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally invasive distal radius plating: are outcomes better?

Introduction Recently, the technique of minimally invasive plate osteosynthesis (MIPO) can also be applied to volar locking plates in distal radius fractures. The advantages of MIPO are fracture healing, a quick return to activities of daily life, and cosmetics as a result of the preservation of the soft tissue compared with conventional plate osteosynthesis. The purpose of the present study wa...

متن کامل

Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures

Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...

متن کامل

Distal radius fractures: Minimally invasive plate osteosynthesis with dorsal bicolumnar locking plates fixation

BACKGROUND Controversy still exists regarding the current treatment modalities for unstable distal radius fractures. There are yet few articles investigating the efficacy of bicolumnar dorsal plating technique, which is designed to minimize tissue dissection while providing sufficiently secure fixation. A clinical study was performed to evaluate the feasibility of the minimally invasive plate o...

متن کامل

Is minimally invasive application by intramedullary osteosynthesis in comparison with volar plating real benefit in the treatment of distal radius fractures?

PURPOSE OF THE STUDY Can minimally invasive intramedullary osteosynthesis of distal radius fractures provide better therapeutic results than multidirectional locking plates. Retrospective study of 68 patients operated for distal radius fractures, 18 were treated with intramedullary X-screw (XSCR) fixation and 50 with the multidirectional angle-stable plate system (APTUS). The evaluation at 1-ye...

متن کامل

Minimally invasive hardware removal after minimally invasive distal radius plate osteosynthesis (MIPO): Feasibility study in a 388 case series.

HYPOTHESIS The aim of the present study was to assess the technical feasibility of minimally invasive volar plate removal following distal radius fracture. MATERIAL AND METHODS Three hundred and eighty-eight plates removed from 387 patients (357 females: mean age, 50 years) were assessed retrospectively. The incision used the primary minimally invasive approach and was closed after plate remo...

متن کامل

Minimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture

Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 48  شماره 

صفحات  -

تاریخ انتشار 2014