Reliability of Microprocessor-Based Relay Protection Devices: Myths and Reality

نویسندگان

  • Vladimir Gurevich
  • V. Gurevich
چکیده

The article examines four basic theses about the ostensibly extremely high reliability of microprocessor-based relay protection (MP) touted by supporters of MP. Through detailed analysis based on many references it is shown that the basis of these theses are widespread myths, and actually MP reliability is lower than the reliability of electromechanical and electronic protective relays on discrete components.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of microprocessor-based relay protection devices - myths and reality

Malfunction of relay protection is one of the main causes of the serious failures that periodically occur in power systems all over the world. According to the North American Electric Reliability Council [1] in 74 % cases the reason for heavy failures in power systems was the incorrect actions of relay protection in trying to avoid the failure. Thus the reliability of a power system depends on ...

متن کامل

Reliability of Microprocessor–based Protective Devices –– Revisited

The article is a continuation of a set of the author’s previous publications about the reliability of the microprocessorbased protective devices. The statistical data introduced by the author coincide with data of other authors and confirm higher reliability of electromechanical relays in comparison with microprocessor-based. The inadequacy of the criterion for estimating the reliability of the...

متن کامل

Impedance-Based Out-of-Step Protection of Generator in the Presence of STATCOM

This paper presents a novel impedance-based approach for out-of-step (OOS) protection of a synchronous generator. The most popular and commonly used approaches for detecting OOS conditions are based on the measurement of positive sequence impedance at relay location. However, FACTS devices change the measured impedance value and thus disrupt the performance of impedance-based relay function. In...

متن کامل

Analysis of fault using microcomputer protection by symmetrical component method

To enhance power supply reliability for the user terminals in the case of the distribution system to avoid interference by the fault again, rapidly complete the automatic identification, positioning, automatic fault isolation, network reconfiguration until the resumption of supply of non-fault section, a microprocessor-based relay protection device has developed. As the fault component theory i...

متن کامل

Effects of CT and VT Connection Point on Distance Protection of Transmission Lines with FACTS Devices

This paper presents the effects of instrument transformers connection points on the measured impedance by distance relays in the presence of Flexible Alternating Current Transmission System (FACTS) devices with series connected branch. Distance relay tripping characteristic itself depends on the power system structural conditions, pre-fault operational conditions, and especially the ground ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009