A pilot trial of bordered polyurethane dressings, tissue adhesive and sutureless devices compared with standard polyurethane dressings for securing short-term arterial catheters.
نویسندگان
چکیده
OBJECTIVES To improve arterial catheter (AC) securement and reduce AC failure; to assess feasibility of a large randomised controlled trial. DESIGN, SETTING AND PARTICIPANTS A four-arm, parallel, randomised, controlled, non-blinded pilot trial with 195 intensive care patients taking part, in a tertiary referral hospital in Brisbane, Australia from May to November 2012. INTERVENTIONS Standard polyurethane (SPU) dressing (controls); bordered polyurethane (BPU) + SPU dressing; tissue adhesive (TA) + SPU dressing; and sutureless securement device (SSD) + SPU dressing (no sutures used). MAIN OUTCOME MEASURES AC failure, ie, complete dislodgement, occlusion (monitor failure, inability to infuse or fluid leaking), pain or infection (local or blood). RESULTS Median AC dwell time was 26.2 hours and was comparable between groups. AC failure occurred in 26/195 patients (13%). AC failure was significantly worse with SPU dressings (10/47 [21%]) than with BPU + SPU dressings (2/ 43 [5%]; P = 0.03), but not significantly different to TA + SPU (6/56 [11%]; P = 0.18) or SSD + SPU (8/49 [16%]; P = 0.61). The dressing applied at AC insertion lasted until AC removal in 68% of controls; 56% of BPU + SPU dressings; 73% of TA + SPU dressings; and 80% of SSD + SPU dressings (all P > 0.05). There were no infections or serious adverse events. Patient and staff satisfaction with all products was high. Median costs (labour and materials) for securement per patient were significantly higher in all groups compared with the control group (SPU, $3.48 [IQR, $3.48-$9.79]; BPU + SPU, $5.07 [IQR, $5.07-$12.99]; SSD + SPU, $10.90 [IQR, $10.90-$10.90]; TA + SPU, $17.70 [IQR, $17.70-$38.36]; all P < 0.01). CONCLUSION AC failure occurred significantly less often with BPU + SPU dressings than with SPU dressings. TA + SPU and SSD + SPU dressings should be further investigated and compared with BPU + SPU dressings as controls. The novel approach of TA + SPU dressings appeared safe and feasible.
منابع مشابه
Novel technologies can provide effective dressing and securement for peripheral arterial catheters: A pilot randomised controlled trial in the operating theatre and the intensive care unit.
BACKGROUND Peripheral arterial catheters are widely used in the care of intensive care patients for continuous blood pressure monitoring and blood sampling, yet failure - from dislodgement, accidental removal, and complications of phlebitis, pain, occlusion and infection - is common. While appropriate methods of dressing and securement are required to reduce these complications that cause failu...
متن کاملCyanoacrylate tissue adhesives - effective securement technique for intravascular catheters: in vitro testing of safety and feasibility.
Partial or complete dislodgement of intravascular catheters remains a significant problem in hospitals despite current securement methods. Cyanoacrylate tissue adhesives (TA) are used to close skin wounds as an alternative to sutures. These adhesives have high mechanical strength and can remain in situ for several days. This study investigated in vitro use of TAs in securing intravascular cathe...
متن کاملRemoval of adhesive wound dressing and its effects on the stratum corneum of the skin: comparison of eight different adhesive wound dressings.
In recent years, adhesive wound dressings have been increasingly applied postoperatively because of their ease of use as they can be kept in place without having to cut and apply surgical tapes and they can cover a wound securely. However, if a wound dressing strongly adheres to the wound, a large amount of stratum corneum is removed from the newly formed epithelium or healthy periwound skin. V...
متن کاملWITHDRAWN: Gauze and tape and transparent polyurethane dressings for central venous catheters.
BACKGROUND Central venous catheters (CVCs) facilitate venous access, allowing the intravenous administration of complex drug treatments, blood products and nutritional support, without the trauma associated with repeated venepuncture. However, CVCs are associated with a risk of infection. Some studies have indicated that the type of dressing used with them may affect the risk of infection. Gauz...
متن کاملA prospective, randomized trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: implications for catheter management.
OBJECTIVES To compare the safety of a conventional polyurethane transparent dressing and a novel highly permeable polyurethane dressing, as compared with standard gauze and tape, as site dressings for pulmonary artery catheters; and to rigorously determine the sources of bloodstream infections deriving from these catheters. DESIGN Prospective, randomized, clinical trial. SETTING General adu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care and resuscitation : journal of the Australasian Academy of Critical Care Medicine
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2014