A 12-Year Experience With Chimney and Periscope Grafts for Treatment of Type I Endoleaks.
نویسندگان
چکیده
PURPOSE To evaluate the midterm outcomes of chimney and/or periscope grafts (CPGs) in patients presenting type I endoleak after a previous endovascular aneurysm repair (EVAR). METHODS Between June 2002 and April 2014, 24 consecutive patients (mean age 73.9±9.2 years; 23 men) presenting a type I endoleak were addressed with CPGs to extend the proximal and/or distal landing zone and to maintain side branch perfusion. Indication for treatment was a type Ia endoleak in 23 (96%) patients and a type Ib endoleak in one. Median interval from the previous EVAR to endoleak treatment with CPGs was 52.2±48.9 months (range 0.2-179). All patients had proximal/distal landing zones precluding any standard endovascular reintervention. Measured outcomes included technical success and perioperative mortality and morbidity. Technical success was defined as a procedure completed as intended, with no secondary procedures within 30 days. Midterm outcomes included survival, CPG patency, endoleaks, and freedom from reintervention. RESULTS Technical success was 96%; a single patient required an additional procedure to seal a recurrent type Ia endoleak. Intraoperative revascularization of all 55 target vessels (2.3/patient) with CPGs was successful. One (4%) patient died within 30 days. Estimated survival at 12, 24, and 36 months was 83%; estimated CPG patency at the same intervals was 94%. Over a mean follow-up of 23.4±29 months, 6 (25%) reinterventions were performed; of these, 4 were secondary to type I endoleak. Aneurysm diameters reduced from 88.3±26 to 85.5±33 mm (p=0.49) over the mean follow-up. CONCLUSION The CPG technique is a safe and effective tool for treatment of type I endoleak after previous EVAR. The CPG technique is feasible even in nonelective patients, with excellent outcomes in terms of patency. Close imaging follow-up is warranted to rule out recurrent or de novo endoleaks.
منابع مشابه
Outcomes of Chimney and/or Periscope Techniques in the Endovascular Management of Complex Aortic Pathologies
BACKGROUND The chimney/periscope technique has been used to address complex aortic pathologies. This study aimed to report the outcomes and experiences of chimney and/or periscope grafts (CPGs) used in the endovascular management of complex aortic pathologies. METHODS Twenty-two patients with complex aortic pathologies were retrospectively studied from January 2013 to August 2016 in two vascu...
متن کاملChimney and periscope grafts observed over 2 years after their use to revascularize 169 renovisceral branches in 77 patients with complex aortic aneurysms.
PURPOSE To evaluate the performance of periscope and/or chimney grafts (CPGs) in the endovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelf devices. METHODS Between February 2002 and August 2012, 77 consecutive patients (62 men; mean age 73±9 years) suffering from pararenal aortic (n=55), thoracoabdominal (n=16), or arch to visceral artery aneurysms (n=6) were t...
متن کاملCT angiography at 24 months demonstrates durability of EVAR with the use of chimney grafts for pararenal aortic pathologies.
PURPOSE To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced ...
متن کاملAortic arch banding procedure for proximal type I endoleak after thoracic endovascular aneurysm repair with the chimney technique
An aortic arch banding procedure was performed on an 82-year-old man for treatment of proximal type I endoleaks 2 days after he had undergone emergency thoracic endovascular aortic repair with the chimney technique for a ruptured aortic arch aneurysm. Contrast-enhanced computed tomography after the second procedure demonstrated significant shrinkage of the aneurysmal sac as well as a complete d...
متن کاملChimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery.
PURPOSE To report the use of parallel grafts to extend the proximal landing zone for stent-graft repair of aortic transection involving an aberrant right subclavian artery (ARSA). CASE REPORT A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2015